PMU application for locating the source of forced oscillations in smart grids

F. Ghorbaniparvar, H. Sangrody
{"title":"PMU application for locating the source of forced oscillations in smart grids","authors":"F. Ghorbaniparvar, H. Sangrody","doi":"10.1109/PECI.2018.8334996","DOIUrl":null,"url":null,"abstract":"Oscillations can cause major stability concern in power systems. It is very important to analyze and locate oscillations quickly so that prompt remedial reactions can be taken to increase the system stability. This paper presents a novel multi-delay self-coherence method to locate source of forced oscillations using measurement data. The derivative constrained minimum variance distortionless response (MVDR) algorithm is used to estimate the coherence spectrum. The Performance of proposed method is evaluated with simulation data that is generated using 16-machine 68-bus model. It is shown through case studies that the proposed method can effectively locate the possible source of forced oscillations.","PeriodicalId":151630,"journal":{"name":"2018 IEEE Power and Energy Conference at Illinois (PECI)","volume":"150 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Power and Energy Conference at Illinois (PECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECI.2018.8334996","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Oscillations can cause major stability concern in power systems. It is very important to analyze and locate oscillations quickly so that prompt remedial reactions can be taken to increase the system stability. This paper presents a novel multi-delay self-coherence method to locate source of forced oscillations using measurement data. The derivative constrained minimum variance distortionless response (MVDR) algorithm is used to estimate the coherence spectrum. The Performance of proposed method is evaluated with simulation data that is generated using 16-machine 68-bus model. It is shown through case studies that the proposed method can effectively locate the possible source of forced oscillations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
定位智能电网中强制振荡源的PMU应用
振荡会引起电力系统的主要稳定性问题。快速分析和定位振荡是非常重要的,这样可以迅速采取补救措施来提高系统的稳定性。提出了一种利用测量数据定位受迫振荡源的多时延自相干方法。采用导数约束最小方差无失真响应(MVDR)算法估计相干谱。用16机68总线模型生成的仿真数据对所提方法的性能进行了评价。算例表明,该方法可以有效地定位可能的强迫振动源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improved active-neutral-point-clamped (I-ANPC) multilevel converter: Fundamental circuit topology, innovative modulation technique, and experimental validation Analysis of multiple revenue streams for privately-owned energy storage systems PMU application for locating the source of forced oscillations in smart grids Decoupled active and reactive power predictive control of impedance source microinverter with LVRT capability Transmission line parameter-free fault location results using field data
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1