A Study of Minimally Invasive Percutaneous Plate Osteosynthesis with Locking Compression Plate for Distal Tibial Fractures

R. Bhatia, S. Gupta, F. Khan
{"title":"A Study of Minimally Invasive Percutaneous Plate Osteosynthesis with Locking Compression Plate for Distal Tibial Fractures","authors":"R. Bhatia, S. Gupta, F. Khan","doi":"10.5958/J.2321-1024.1.2.041","DOIUrl":null,"url":null,"abstract":"Introduction: Distal tibial fractures present a serious challenge, often requiring operative treatment but are very difficult to deal with. Fixation with locking compression plate (LCP) by minimally invasive percutaneous plate Osteosynthesis (MIPPO) technique has emerged as an alternative treatment option because it respects biology of distal tibia and fracture hematoma and also provides biomechanically sound fixation. The aim of this study was to find out the results of MIPPO with LCP for distal tibial fractures in our set up. Method: Twenty nine patients were treated by minimally invasive technique (MIPPO with LCP) for distal tibial fracture, only 24 patients were having proper follow-up. These 24 patients-(AO classification: 14 type A, 5 type B & 5 type C) were prospectively followed up. Twenty two male and two female patients with a mean age of 35 years were included. Results: In our study 17 (70.83%) patients had excellent results, 6(25%) patients had good results & 1(4.17 %) patient was having poor result. One patient had delayed union & required bone grafting. Malleolar skin irritation and pain due to prominent hardware was observed in two patients. One patient had hardware failure due to non-compliance. Another patient had infection in fibular fixation site that required hardware removal. Conclusion: The MIPPO technique for distal tibia has shown good results with many additional advantages over the conventional methods. It appears to be a reliable & effective method of stabilisation for these fractures. Rigid fixation allows the patient to be mobilized earlier & complications like displacement, contractures & stiffness can be avoided.","PeriodicalId":113416,"journal":{"name":"International journal of contemporary surgery","volume":"218 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of contemporary surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5958/J.2321-1024.1.2.041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction: Distal tibial fractures present a serious challenge, often requiring operative treatment but are very difficult to deal with. Fixation with locking compression plate (LCP) by minimally invasive percutaneous plate Osteosynthesis (MIPPO) technique has emerged as an alternative treatment option because it respects biology of distal tibia and fracture hematoma and also provides biomechanically sound fixation. The aim of this study was to find out the results of MIPPO with LCP for distal tibial fractures in our set up. Method: Twenty nine patients were treated by minimally invasive technique (MIPPO with LCP) for distal tibial fracture, only 24 patients were having proper follow-up. These 24 patients-(AO classification: 14 type A, 5 type B & 5 type C) were prospectively followed up. Twenty two male and two female patients with a mean age of 35 years were included. Results: In our study 17 (70.83%) patients had excellent results, 6(25%) patients had good results & 1(4.17 %) patient was having poor result. One patient had delayed union & required bone grafting. Malleolar skin irritation and pain due to prominent hardware was observed in two patients. One patient had hardware failure due to non-compliance. Another patient had infection in fibular fixation site that required hardware removal. Conclusion: The MIPPO technique for distal tibia has shown good results with many additional advantages over the conventional methods. It appears to be a reliable & effective method of stabilisation for these fractures. Rigid fixation allows the patient to be mobilized earlier & complications like displacement, contractures & stiffness can be avoided.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
微创经皮锁定加压钢板内固定治疗胫骨远端骨折的研究
胫骨远端骨折是一个严重的挑战,通常需要手术治疗,但很难处理。微创经皮钢板成骨(MIPPO)技术的锁定加压钢板(LCP)固定已成为一种替代治疗选择,因为它尊重胫骨远端和骨折血肿的生物学特性,并提供生物力学上良好的固定。本研究的目的是找出MIPPO与LCP治疗胫骨远端骨折的结果。方法:对29例胫骨远端骨折患者采用微创技术(MIPPO + LCP)治疗,其中24例进行了随访。对24例患者(AO分型:A型14例,B型5例,C型5例)进行前瞻性随访。包括22名男性和2名女性患者,平均年龄35岁。结果:优17例(70.83%),良6例(25%),差1例(4.17%)。1例患者延迟愈合,需要植骨。2例患者因硬体突出引起踝部皮肤刺激和疼痛。一名患者因不遵守规定而发生硬件故障。另一名患者腓骨固定部位感染,需要取下固定物。结论:MIPPO技术在胫骨远端有较好的效果,与传统方法相比有许多优点。这似乎是稳定这些骨折的可靠和有效的方法。刚性固定可使患者更早活动,避免移位、挛缩和僵硬等并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative Study of Collagen Density, Fibroblast, and Neovascularization in Tracheal Defect Reconstruction with Primary Repair and External Oblique Muscle Aponeurosis Patch (A Novel Study with New Zealand Rabbit) Double Parathyroid Adenoma: Culprit Behind A Non- Functioning Kidney Role of Probiotics in Reducing GERD Effects of Immediate Post Operative Orthopaedic Rehabilitation in Lower Limb Open Reduction Internal Fixation’s Orthopaedic Surgeries to Reduce Fear Avoidance Behaviour and Early Ambulation To Study the Repair of Incisional Hernia by Preperitoneal Meshplasty
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1