{"title":"Acoustic signal-based cable terminal partial discharge detection and diagnosis","authors":"Ting Ye, Hang Ji, Xing Lei, Qiang Xu, Shengfu Zhang, Ruitian Fan","doi":"10.1109/CEECT55960.2022.10030321","DOIUrl":null,"url":null,"abstract":"In recent years, power cables have been used in large quantities in urban transmission and distribution networks, however, cable accessory faults show an increasing trend year by year. In this paper, based on the study of the principles of air acoustic local discharge and phased array acoustic local discharge, an integrated high voltage cable partial discharge acoustic device based on air acoustic local discharge and phased array acoustic local discharge detection is developed. Through laboratory tests and field together with the application results of grounded transformer cable terminals, it is concluded that for the type of discharge along the surface of the cable terminal, the integrated partial discharge detection of air acoustic local discharge and phased array acoustic local discharge has higher sensitivity than the single phased array acoustic local discharge detection and infrared partial discharge detection. The application effect shows that the sensitivity and efficiency of the detection of partial discharge of cable terminals can be improved based on the integrated air-acoustic local discharge and phased array acoustic partial discharge detection device.","PeriodicalId":187017,"journal":{"name":"2022 4th International Conference on Electrical Engineering and Control Technologies (CEECT)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 4th International Conference on Electrical Engineering and Control Technologies (CEECT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEECT55960.2022.10030321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In recent years, power cables have been used in large quantities in urban transmission and distribution networks, however, cable accessory faults show an increasing trend year by year. In this paper, based on the study of the principles of air acoustic local discharge and phased array acoustic local discharge, an integrated high voltage cable partial discharge acoustic device based on air acoustic local discharge and phased array acoustic local discharge detection is developed. Through laboratory tests and field together with the application results of grounded transformer cable terminals, it is concluded that for the type of discharge along the surface of the cable terminal, the integrated partial discharge detection of air acoustic local discharge and phased array acoustic local discharge has higher sensitivity than the single phased array acoustic local discharge detection and infrared partial discharge detection. The application effect shows that the sensitivity and efficiency of the detection of partial discharge of cable terminals can be improved based on the integrated air-acoustic local discharge and phased array acoustic partial discharge detection device.