Autocorrelation Function for Predicting Arrhythmic Recurrences in Patients Undergoing Persistent Atrial Fibrillation Ablation

R. Abad, E. Franco, S. Ruipérez-Campillo, C. Lozano, F. Castells, J. Moreno
{"title":"Autocorrelation Function for Predicting Arrhythmic Recurrences in Patients Undergoing Persistent Atrial Fibrillation Ablation","authors":"R. Abad, E. Franco, S. Ruipérez-Campillo, C. Lozano, F. Castells, J. Moreno","doi":"10.22489/CinC.2022.424","DOIUrl":null,"url":null,"abstract":"Persistent atrial fibrillation ablation has a high recurrence rate. In this work, we performed an analysis of bipolar intracavitary signals obtained with a conventional 24-pole diagnostic catheter (Woven Orbiter) placed in the right atrium and coronary sinus in a cohort of patients with persistent atrial fibrillation undergoing ablation to detect features predictive of acute procedural success (conversion to sinus rhythm during ablation) and the occurrence of recurrences. The goal is to arrive at a quantitative description of the degree of randomness of the atrial response in atrial fibrillation and to demonstrate the presence of hidden periodic components. This was done by the determination of the autocorrelation function. Results showed that higher correlation in relative maximum peaks, and a lower dominant atrial frequency (greater distance between relative amplitude maxima) may be associated with a greater likelihood of achieving reversion to sinus rhythm and lower probability of recurrences. A larger study is needed to draw conclusions.","PeriodicalId":117840,"journal":{"name":"2022 Computing in Cardiology (CinC)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22489/CinC.2022.424","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Persistent atrial fibrillation ablation has a high recurrence rate. In this work, we performed an analysis of bipolar intracavitary signals obtained with a conventional 24-pole diagnostic catheter (Woven Orbiter) placed in the right atrium and coronary sinus in a cohort of patients with persistent atrial fibrillation undergoing ablation to detect features predictive of acute procedural success (conversion to sinus rhythm during ablation) and the occurrence of recurrences. The goal is to arrive at a quantitative description of the degree of randomness of the atrial response in atrial fibrillation and to demonstrate the presence of hidden periodic components. This was done by the determination of the autocorrelation function. Results showed that higher correlation in relative maximum peaks, and a lower dominant atrial frequency (greater distance between relative amplitude maxima) may be associated with a greater likelihood of achieving reversion to sinus rhythm and lower probability of recurrences. A larger study is needed to draw conclusions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
预测持续性房颤消融患者心律失常复发的自相关功能
持续性房颤消融有很高的复发率。在这项工作中,我们对一组接受消融治疗的持续性心房颤动患者进行了双极腔内信号分析,该信号是通过将传统的24极诊断导管(Woven Orbiter)放置在右心房和冠状动脉窦内获得的,以检测急性手术成功(消融期间转化为窦性心律)和复发的预测特征。目的是对房颤中心房反应的随机性程度进行定量描述,并证明存在隐藏的周期性成分。这是通过确定自相关函数来实现的。结果显示,相对最大峰值的相关性较高,较低的主导心房频率(相对最大振幅之间的距离较大)可能与更大的可能性实现窦性心律恢复和较低的复发概率相关。需要更大规模的研究才能得出结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Nonlinear Dynamic Response of Intrapartum Fetal Heart Rate to Uterine Pressure Heart Pulse Demodulation from Emfit Mattress Sensor Using Spectral and Source Separation Techniques Automated Algorithm for QRS Detection in Cardiac Arrest Patients with PEA Extraction Algorithm for Morphologically Preserved Non-Invasive Multi-Channel Fetal ECG Improved Pulse Pressure Estimation Based on Imaging Photoplethysmographic Signals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1