{"title":"A Wearable Inertial Sensing Technology for Clinical Assessment of Tremor","authors":"H. Powell, M. Hanson, J. Lach","doi":"10.1109/BIOCAS.2007.4463296","DOIUrl":null,"url":null,"abstract":"TEMPO (Technology-Enabled Medical Precision Observation) 1.0 is a novel, first-generation, wearable data collection and analysis platform for assessment of a variety of human movement disorders, including tremor. It enables quantitative, objective, and continuous measurement of movement with minimal invasiveness and inconvenience to the patient and clinician, respectively. This system meets requirements for wearability, data storage, sampling rate, number of sensors, interface methods, and form factor, which are necessary for applications on person. In addition to the design and development of a basic data acquisition device, various circuits and systems were engineered to interface wearable, triaxial MEMS inertial sensors. Furthermore, custom data analysis software that processes datasets collected from the device and sensors, was created, and has demonstrated clinical utility in the analysis of tremor. Data processing techniques include a unique filtering scheme and a novel application of cross-correlation. The analysis was conducted pre- and post-operatively, in conjunction with the University of Virginia's Department of Neurosurgery, for a study of deep brain stimulation efficacy. This paper presents the engineering of and experimental results obtained with TEMPO 1.0 technology in the clinical assessment of tremor.","PeriodicalId":273819,"journal":{"name":"2007 IEEE Biomedical Circuits and Systems Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Biomedical Circuits and Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2007.4463296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20
Abstract
TEMPO (Technology-Enabled Medical Precision Observation) 1.0 is a novel, first-generation, wearable data collection and analysis platform for assessment of a variety of human movement disorders, including tremor. It enables quantitative, objective, and continuous measurement of movement with minimal invasiveness and inconvenience to the patient and clinician, respectively. This system meets requirements for wearability, data storage, sampling rate, number of sensors, interface methods, and form factor, which are necessary for applications on person. In addition to the design and development of a basic data acquisition device, various circuits and systems were engineered to interface wearable, triaxial MEMS inertial sensors. Furthermore, custom data analysis software that processes datasets collected from the device and sensors, was created, and has demonstrated clinical utility in the analysis of tremor. Data processing techniques include a unique filtering scheme and a novel application of cross-correlation. The analysis was conducted pre- and post-operatively, in conjunction with the University of Virginia's Department of Neurosurgery, for a study of deep brain stimulation efficacy. This paper presents the engineering of and experimental results obtained with TEMPO 1.0 technology in the clinical assessment of tremor.
TEMPO (Technology-Enabled Medical Precision Observation) 1.0是一种全新的第一代可穿戴数据收集和分析平台,用于评估包括震颤在内的各种人类运动障碍。它能够定量、客观和连续地测量运动,对患者和临床医生分别具有最小的侵入性和不便。该系统在可穿戴性、数据存储、采样率、传感器数量、接口方式、外形尺寸等方面满足了人体应用的要求。除了设计和开发基本的数据采集设备外,还设计了各种电路和系统来连接可穿戴的三轴MEMS惯性传感器。此外,定制数据分析软件,处理从设备和传感器收集的数据集,被创建,并已证明在临床应用分析震颤。数据处理技术包括独特的滤波方案和互相关的新应用。这项分析是与弗吉尼亚大学神经外科联合进行的,目的是研究深部脑刺激的效果。本文介绍了TEMPO 1.0技术在震颤临床评价中的工程原理和实验结果。