EXPERIMENTAL RESEARCH ON COMPRESSION FOAM COOLING DURING ITS DELIVERY AT DIFFERENT AMBIENT TEMPERATURE MODES

G. A.
{"title":"EXPERIMENTAL RESEARCH ON COMPRESSION FOAM COOLING DURING ITS DELIVERY AT DIFFERENT AMBIENT TEMPERATURE MODES","authors":"G. A.","doi":"10.25257/fe.2021.4.40-44","DOIUrl":null,"url":null,"abstract":"Purpose. The article describes methodology for conducting research on parameters of compression foam cooling during its delivery through hose-pump systems depending on the operating modes of the foam generating installation. The impact of mass consumption of compression foam on its cooling at low temperatures has been examined. The application of a mathematical model of air-foam mixture movement in hose-pump systems at different temperature modes has been substantiated. Methods. Empirical method-experiment has been used for research. Findings. A number of experiments have been carried out to confirm the developed model of compression foam moving in hose-pump systems at different temperature modes. A mobile installation for generating and delivering compression foam has been used as the object of the research. Inaccuracy in calculations obtained with the help of a mathematical model in comparison with the experimental data is 10% which makes a possible to claim that the model of compression foam moving in hose-pump systems at different temperature modes has been chosen properly. Research application field. According to the obtained data, it is possible to plan means and forces of fire units for extinguishing fires using compression foam at low temperatures. Conclusions. The developed mathematical model of compression foam movement during its delivery through hose-pump systems is confirmed by experimental data. The dependence of mass consumption impact on compression foam cooling when it is delivered through fire hoses at low temperatures has been obtained experimentally.","PeriodicalId":105490,"journal":{"name":"Fire and Emergencies: prevention, elimination","volume":"110 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire and Emergencies: prevention, elimination","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25257/fe.2021.4.40-44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose. The article describes methodology for conducting research on parameters of compression foam cooling during its delivery through hose-pump systems depending on the operating modes of the foam generating installation. The impact of mass consumption of compression foam on its cooling at low temperatures has been examined. The application of a mathematical model of air-foam mixture movement in hose-pump systems at different temperature modes has been substantiated. Methods. Empirical method-experiment has been used for research. Findings. A number of experiments have been carried out to confirm the developed model of compression foam moving in hose-pump systems at different temperature modes. A mobile installation for generating and delivering compression foam has been used as the object of the research. Inaccuracy in calculations obtained with the help of a mathematical model in comparison with the experimental data is 10% which makes a possible to claim that the model of compression foam moving in hose-pump systems at different temperature modes has been chosen properly. Research application field. According to the obtained data, it is possible to plan means and forces of fire units for extinguishing fires using compression foam at low temperatures. Conclusions. The developed mathematical model of compression foam movement during its delivery through hose-pump systems is confirmed by experimental data. The dependence of mass consumption impact on compression foam cooling when it is delivered through fire hoses at low temperatures has been obtained experimentally.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同环境温度模式下压缩泡沫输送冷却的实验研究
目的。本文描述了根据泡沫产生装置的运行模式,通过软管-泵系统进行压缩泡沫冷却过程中参数研究的方法。研究了压缩泡沫的大量消耗对其低温冷却的影响。本文证实了空气-泡沫混合物在不同温度模式下在软管-泵系统中的运动数学模型的应用。方法。研究采用实证方法-实验法。发现。为了验证所建立的压缩泡沫在不同温度模式下在软管-泵系统中的运动模型,进行了大量的实验。研究对象是一种用于产生和输送压缩泡沫的移动装置。与实验数据相比,数学模型计算的误差为10%,可以认为在不同温度模式下软管-泵系统中压缩泡沫运动的模型选择是正确的。研究应用领域。根据获得的数据,可以计划在低温下使用压缩泡沫灭火的消防单位的手段和力量。结论。所建立的压缩泡沫在软管-泵输送过程中的运动数学模型得到了实验数据的验证。实验得到了低温下通过消防软管输送压缩泡沫时,质量消耗对压缩泡沫冷却的依赖关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Study of strength characteristics of long-term and rapidly deployable geodesic dome shelters for the needs of EMERCOM airmobile groups Choosing of fire extinguishing medium in coal mines on the basis of accident autocorrelation analysis Emergency risk reduction technologies at tunnel type road junctions Method of improving systems ensuring reduction of fire and industrial hazard Method of determining optimal time for professional training of fire-rescue units chiefs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1