Application of B-splines FFD image registration in breast cancer radiotherapy planning

Marek Wodzinski, A. Skalski, P. Kedzierawski, T. Kuszewski
{"title":"Application of B-splines FFD image registration in breast cancer radiotherapy planning","authors":"Marek Wodzinski, A. Skalski, P. Kedzierawski, T. Kuszewski","doi":"10.1109/IWSSIP.2017.7965578","DOIUrl":null,"url":null,"abstract":"Localization of a resected tumor lodge after a breast cancer surgery is a challenging task for the radiotherapy planning. Currently, the problem is handled by creating radiation dose margins, which take into account the lack of information about lodge localization. We propose an alternative approach based on the image registration techniques, that aims to align computed tomography 3D images before and after surgery and to estimate the resected tumor lodge localization. The rigid registration and free-form deformations based on B-Splines are evaluated with additional 3D images preprocessing and analytical gradient calculation to speed-up the registration process. The correctness and usefulness are evaluated using target registration error, visual inspection, and physician opinion. The results demonstrate that the usage of image registration techniques can improve the quality of the radiotherapy planning.","PeriodicalId":302860,"journal":{"name":"2017 International Conference on Systems, Signals and Image Processing (IWSSIP)","volume":"275 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Systems, Signals and Image Processing (IWSSIP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWSSIP.2017.7965578","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Localization of a resected tumor lodge after a breast cancer surgery is a challenging task for the radiotherapy planning. Currently, the problem is handled by creating radiation dose margins, which take into account the lack of information about lodge localization. We propose an alternative approach based on the image registration techniques, that aims to align computed tomography 3D images before and after surgery and to estimate the resected tumor lodge localization. The rigid registration and free-form deformations based on B-Splines are evaluated with additional 3D images preprocessing and analytical gradient calculation to speed-up the registration process. The correctness and usefulness are evaluated using target registration error, visual inspection, and physician opinion. The results demonstrate that the usage of image registration techniques can improve the quality of the radiotherapy planning.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
b样条FFD图像配准在乳腺癌放疗规划中的应用
乳腺癌手术后切除肿瘤的定位是放疗计划中的一项具有挑战性的任务。目前,这个问题是通过建立辐射剂量边界来解决的,这考虑到缺乏关于小屋定位的信息。我们提出了一种基于图像配准技术的替代方法,旨在对手术前后的计算机断层扫描3D图像进行对齐,并估计切除肿瘤的位置。对基于b样条的刚性配准和自由变形进行了评价,并对三维图像进行了预处理和解析梯度计算,加快了配准过程。使用目标注册误差、目视检查和医生意见来评估其正确性和有效性。结果表明,图像配准技术的应用可以提高放疗计划的质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Efficient frame-compatible stereoscopic video coding using HEVC screen content coding Reinforcement learning for video encoder control in HEVC Software and hardware HEVC encoding Ensemble of CNN and rich model for steganalysis IVQAD 2017: An immersive video quality assessment database
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1