Investigative Study on Emissions Level and Cost Analysis of Diesel Powered and Solar PV-Diesel Hybrid Systems

O. Ajide, Chioma Irene Eze, T. T. Olugasa, O. S. Ismail
{"title":"Investigative Study on Emissions Level and Cost Analysis of Diesel Powered and Solar PV-Diesel Hybrid Systems","authors":"O. Ajide, Chioma Irene Eze, T. T. Olugasa, O. S. Ismail","doi":"10.4236/wjet.2021.93034","DOIUrl":null,"url":null,"abstract":"In this work, a comparative study on emissions and cost implications of diesel powered and solar photovoltaic-diesel hybrid systems was carried out for three commercial banks. With the aid of HOMER Pro software, meteorological data, energy demand, system component data, capital and operating costs were used for analysis of the two systems. The results showed that in Bank A, the diesel generator alone releases 111,618 kg/yr of Carbon dioxide while the hybrid system releases 41,618 kg/yr of Carbon dioxide. For Bank B the quantity of carbon dioxide emissions released from the diesel generator in Bank B is 53,830 kg/yr, while the carbon dioxide released from the hybrid energy system is 24,082 kg/yr. For Bank C, the diesel generator alone released 177,799 kg/yr of Carbon dioxide and 129,060 kg/yr of carbon dioxide was released from the hybrid system. This suggests that the diesel generator alone releases more emissions when compared with the hybrid system in all the three banks. The Net present cost of energy and levelized cost of energy were used to find out the cost effectiveness of hybrid systems. The results showed that the levelized cost of energy for the generator alone and hybrid system, respectively in Bank A is $0.713 and $0.343. While for Bank B, it is $0.568 and $0.2553. Finally for Bank C, it was $0.731 and $0.556. Therefore, solar-diesel hybrid system has a comparatively low emission and can be considered as a more economical option for electricity generation.","PeriodicalId":344331,"journal":{"name":"World Journal of Engineering and Technology","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/wjet.2021.93034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, a comparative study on emissions and cost implications of diesel powered and solar photovoltaic-diesel hybrid systems was carried out for three commercial banks. With the aid of HOMER Pro software, meteorological data, energy demand, system component data, capital and operating costs were used for analysis of the two systems. The results showed that in Bank A, the diesel generator alone releases 111,618 kg/yr of Carbon dioxide while the hybrid system releases 41,618 kg/yr of Carbon dioxide. For Bank B the quantity of carbon dioxide emissions released from the diesel generator in Bank B is 53,830 kg/yr, while the carbon dioxide released from the hybrid energy system is 24,082 kg/yr. For Bank C, the diesel generator alone released 177,799 kg/yr of Carbon dioxide and 129,060 kg/yr of carbon dioxide was released from the hybrid system. This suggests that the diesel generator alone releases more emissions when compared with the hybrid system in all the three banks. The Net present cost of energy and levelized cost of energy were used to find out the cost effectiveness of hybrid systems. The results showed that the levelized cost of energy for the generator alone and hybrid system, respectively in Bank A is $0.713 and $0.343. While for Bank B, it is $0.568 and $0.2553. Finally for Bank C, it was $0.731 and $0.556. Therefore, solar-diesel hybrid system has a comparatively low emission and can be considered as a more economical option for electricity generation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
柴油动力和太阳能-柴油混合动力系统排放水平及成本分析的调查研究
在这项工作中,对三家商业银行进行了柴油动力和太阳能光伏-柴油混合动力系统的排放和成本影响的比较研究。借助HOMER Pro软件,利用气象数据、能源需求、系统组成数据、资金和运行成本对两个系统进行了分析。结果表明,在A银行,单独柴油发电机释放111,618 kg/yr的二氧化碳,而混合动力系统释放41,618 kg/yr的二氧化碳。对于B银行,B银行柴油发电机的二氧化碳排放量为53,830 kg/yr,而混合能源系统的二氧化碳排放量为24,082 kg/yr。对于C银行,仅柴油发电机就释放了177,799千克/年的二氧化碳,混合动力系统释放了129,060千克/年的二氧化碳。这表明,与所有三个银行的混合动力系统相比,柴油发电机单独释放更多的排放。利用净当前能源成本和平准化能源成本来确定混合动力系统的成本效益。结果表明,在A银行中,发电机单独发电和混合发电系统的平均能源成本分别为0.713美元和0.343美元。而对于B银行,它是0.568美元和0.2553美元。最后,对于银行C,它是0.731美元和0.556美元。因此,太阳能-柴油混合动力系统的排放相对较低,可以被认为是一种更经济的发电选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Research on Influencing Factors of Reservoir Construction Risk Based on Interpretative Structural Modeling Preliminary Exploration on the Application of Saussure Sign Concept in Bio-Inspired Design: A Case of Tiantoushui Doll-Design Comparative Analysis of Hybrid Controllers of Done Systems (UPFC) and Interphase Power Regulators Type RPI 30p15 on Contingency Management in Electrical Networks Bureaucratic Factors Impeding the Delivery of Infrastructure at the Metropolitan Municipal and District Assemblies (MMDAs) in Ghana Summary of Application of Fuzzy Mathematics in Construction Project Management
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1