{"title":"The skin 2D electrobioimpedance response to a remote non-thermal mm-EMF exposure: phenomenological study","authors":"Y. F. Babich","doi":"10.1109/ICBEM.1998.666404","DOIUrl":null,"url":null,"abstract":"A new skin impedance imaging device enabled us to monitor the Skin Electro-bioimpedance Relief (SER) processes such as initial autowaves and induced wave-like dynamics. The SER's response to a remote non-thermal mm-EMF input was investigated in the skin \"bioactive\" zone (MC7; 20/spl times/40 mm) of healthy subjects and subjects suffering from vegetal-vascular dysfunction. No significant changes were seen in healthy subjects. In unhealthy subjects, in response to switching on of the mm-EMF, a speed of the dominating coherent structure (CS) increased sharply from fractions of mm/min to about 5-7 mm/min; suppression of the neighbouring CS was also observed. In response to switching off of the mm-EMF input, a reverse jump (5-7 mm/min) of the dominating CS back front and reemergence of the neighbouring CS was seen.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBEM.1998.666404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A new skin impedance imaging device enabled us to monitor the Skin Electro-bioimpedance Relief (SER) processes such as initial autowaves and induced wave-like dynamics. The SER's response to a remote non-thermal mm-EMF input was investigated in the skin "bioactive" zone (MC7; 20/spl times/40 mm) of healthy subjects and subjects suffering from vegetal-vascular dysfunction. No significant changes were seen in healthy subjects. In unhealthy subjects, in response to switching on of the mm-EMF, a speed of the dominating coherent structure (CS) increased sharply from fractions of mm/min to about 5-7 mm/min; suppression of the neighbouring CS was also observed. In response to switching off of the mm-EMF input, a reverse jump (5-7 mm/min) of the dominating CS back front and reemergence of the neighbouring CS was seen.