Biomagnetic micro massage therapy basic research 生物磁微按摩疗法基础研究
D. Susič
It has been shown by a number of authors that a pulsing electromagnetic field creates beneficial effects on fractures, pseudoarthrosis, etc. This research represents an introduction of a new method in the low frequency electromagnetic field therapy, called the Biomagnetic Micro Massage Therapy (BMMT). Experiments were performed on rats under anaesthesia. The right lower limb each rat was traumatized using a standard technique. It has been observed that a significantly lower degree of swelling in animals exposed to BMMT, compared to the control group and others.
许多作者已经证明,脉冲电磁场对骨折、假关节等产生有益的影响。本研究介绍了一种低频电磁场治疗的新方法,称为生物磁微按摩疗法(BMMT)。实验在大鼠麻醉状态下进行。每只大鼠的右下肢使用标准技术进行创伤。据观察,与对照组和其他对照组相比,暴露于BMMT的动物肿胀程度明显较低。
{"title":"Biomagnetic micro massage therapy basic research","authors":"D. Susič","doi":"10.1109/ICBEM.1998.666420","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666420","url":null,"abstract":"It has been shown by a number of authors that a pulsing electromagnetic field creates beneficial effects on fractures, pseudoarthrosis, etc. This research represents an introduction of a new method in the low frequency electromagnetic field therapy, called the Biomagnetic Micro Massage Therapy (BMMT). Experiments were performed on rats under anaesthesia. The right lower limb each rat was traumatized using a standard technique. It has been observed that a significantly lower degree of swelling in animals exposed to BMMT, compared to the control group and others.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116762619","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Measurements of the effectiveness of antenna screens for protection of the head from mobile phone radiation 天线屏保护头部免受移动电话辐射的有效性测量
S. Jenvey
Measurements have been taken of the electromagnetic field distribution around a mobile phone which was transmitting CW at 890 MHz. The measurements were taken using a mobile phone with a short monopole antenna and were then repeated with a reflector (that is supposed to protect the head from radiation) interposed between the head and the radiating antenna. Measurements of field magnitude and phase were made so that animations of the propagating fields could be observed. Comparisons of the field distributions and conclusions regarding the effectiveness of the reflector could then be made.
测量了在890兆赫频率下传输连续波的移动电话周围的电磁场分布。测量是用一个带有短单极天线的手机进行的,然后在头部和辐射天线之间插入一个反射器(应该是保护头部免受辐射)来重复测量。测量了场的大小和相位,以便观察传播场的动画。然后可以比较场分布并得出有关反射器有效性的结论。
{"title":"Measurements of the effectiveness of antenna screens for protection of the head from mobile phone radiation","authors":"S. Jenvey","doi":"10.1109/ICBEM.1998.666462","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666462","url":null,"abstract":"Measurements have been taken of the electromagnetic field distribution around a mobile phone which was transmitting CW at 890 MHz. The measurements were taken using a mobile phone with a short monopole antenna and were then repeated with a reflector (that is supposed to protect the head from radiation) interposed between the head and the radiating antenna. Measurements of field magnitude and phase were made so that animations of the propagating fields could be observed. Comparisons of the field distributions and conclusions regarding the effectiveness of the reflector could then be made.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125032929","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Observation of human impedance at 50 kHz for analysis of acupuncture points 观察人体阻抗在50千赫的穴位分析
Suhariningsih, H. Kanai
Human skin impedance was measured at 50 kHz. The measurements were performed on putative acupuncture points and surrounding sites of the pericardium and lung meridian located on the skin between the metacarpophalangeal joints and elbow of a healthy volunteer. Results showed acupuncture point could be identified by skin impedance measured with a 2 mm diameter searching electrode.
在50 kHz时测量人体皮肤阻抗。测量是在健康志愿者掌指关节和肘部之间皮肤上假定的心包和肺经络的穴位和周围部位进行的。结果表明,用直径为2 mm的搜索电极测量皮肤阻抗可以识别穴位。
{"title":"Observation of human impedance at 50 kHz for analysis of acupuncture points","authors":"Suhariningsih, H. Kanai","doi":"10.1109/ICBEM.1998.666403","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666403","url":null,"abstract":"Human skin impedance was measured at 50 kHz. The measurements were performed on putative acupuncture points and surrounding sites of the pericardium and lung meridian located on the skin between the metacarpophalangeal joints and elbow of a healthy volunteer. Results showed acupuncture point could be identified by skin impedance measured with a 2 mm diameter searching electrode.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126102110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Dolphin sonar pulse intervals and human resonance characteristics 海豚声纳脉冲间隔与人体共振特性
S. Birch
Dolphin assisted therapy involves dolphins because of their purported therapeutic properties. The physiological effect of dolphin contact on human beings is characterised by noticeable modifications in brain electrical activity. The actual mechanism of action is still unclear. Through analysis of dolphin sonar signals, and comparison with mechanical resonance frequencies of the human body, a possible mechanism of action becomes apparent and is presented here.
海豚辅助疗法涉及海豚,因为它们据称具有治疗特性。与海豚接触对人的生理影响的特点是大脑电活动的明显改变。实际的作用机制尚不清楚。通过对海豚声纳信号的分析,并与人体的机械共振频率进行比较,得出了一种可能的作用机制。
{"title":"Dolphin sonar pulse intervals and human resonance characteristics","authors":"S. Birch","doi":"10.1109/ICBEM.1998.666435","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666435","url":null,"abstract":"Dolphin assisted therapy involves dolphins because of their purported therapeutic properties. The physiological effect of dolphin contact on human beings is characterised by noticeable modifications in brain electrical activity. The actual mechanism of action is still unclear. Through analysis of dolphin sonar signals, and comparison with mechanical resonance frequencies of the human body, a possible mechanism of action becomes apparent and is presented here.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128539595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Effective bioimpedance spectroscopy method for evaluation of body cell water compartments 有效生物阻抗谱法评价人体细胞水室
R. Fiorini, G. Dacquino, G. Arrigo, C.L. Selicato, G. D’Amico
The traditional Cole or CFC basic model might offer too coarse estimations in personalized haemodialytic treatment. To take advantage of the full information content offered by BIS instrumentation the traditional CFC model can be extended into a more convenient model: the Extended CFC (ECFC) model. The ECFC model is used to fit raw bioimpedance measurements to increase the overall estimation accuracy of Resistance and Reactance terms. An experimental comparison between CPC, ECFC model simulations, and experimental data is presented. Experimental results show that higher accuracies (at least a tenfold improvement) over the traditional CFC model are easily achieved.
传统的Cole或CFC基本模型可能在个性化血液透析治疗中提供过于粗糙的估计。为了利用BIS仪器提供的全部信息内容,可以将传统的CFC模型扩展为更方便的模型:扩展CFC (ECFC)模型。ECFC模型用于拟合原始生物阻抗测量,以提高电阻和电抗项的整体估计精度。对CPC、ECFC模型的模拟结果与实验数据进行了对比。实验结果表明,与传统的CFC模型相比,该模型可以很容易地实现更高的精度(至少提高十倍)。
{"title":"Effective bioimpedance spectroscopy method for evaluation of body cell water compartments","authors":"R. Fiorini, G. Dacquino, G. Arrigo, C.L. Selicato, G. D’Amico","doi":"10.1109/ICBEM.1998.666463","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666463","url":null,"abstract":"The traditional Cole or CFC basic model might offer too coarse estimations in personalized haemodialytic treatment. To take advantage of the full information content offered by BIS instrumentation the traditional CFC model can be extended into a more convenient model: the Extended CFC (ECFC) model. The ECFC model is used to fit raw bioimpedance measurements to increase the overall estimation accuracy of Resistance and Reactance terms. An experimental comparison between CPC, ECFC model simulations, and experimental data is presented. Experimental results show that higher accuracies (at least a tenfold improvement) over the traditional CFC model are easily achieved.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129303468","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Analysis of amino acid parameters in the Resonant Recognition Model 共振识别模型中氨基酸参数分析
E. Pirogova, Q. Fang, E. Lazoura, Irena Cosic
The Resonant Recognition Model (RRM) is a physicomathematical model developed for analysing protein and nucleic acid sequences. Previously, the electron-ion interaction potentials (EIIP) of amino acids have been used to determine the characteristic frequency of biologically related proteins. In this study, the effect of various other amino acid parameters on periodicity, obtained using the RRM, were assessed. Three functionally unrelated protein groups (glucagons, lysozymes and haemoglobins) were used as test examples. However, no single parameter was found to be a good representative of biological activity.
共振识别模型(RRM)是一种用于分析蛋白质和核酸序列的物理数学模型。以前,氨基酸的电子-离子相互作用电位(EIIP)已被用来确定生物相关蛋白的特征频率。在这项研究中,评估了使用RRM获得的各种其他氨基酸参数对周期性的影响。三个功能不相关的蛋白组(胰高血糖素、溶菌酶和血红蛋白)作为测试例。然而,没有发现单一参数能很好地代表生物活性。
{"title":"Analysis of amino acid parameters in the Resonant Recognition Model","authors":"E. Pirogova, Q. Fang, E. Lazoura, Irena Cosic","doi":"10.1109/ICBEM.1998.666400","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666400","url":null,"abstract":"The Resonant Recognition Model (RRM) is a physicomathematical model developed for analysing protein and nucleic acid sequences. Previously, the electron-ion interaction potentials (EIIP) of amino acids have been used to determine the characteristic frequency of biologically related proteins. In this study, the effect of various other amino acid parameters on periodicity, obtained using the RRM, were assessed. Three functionally unrelated protein groups (glucagons, lysozymes and haemoglobins) were used as test examples. However, no single parameter was found to be a good representative of biological activity.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129673703","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Investigation of analogue and digital mobile phone low frequency radiation spectrum characteristics 模拟与数字手机低频辐射频谱特性研究
B. Heath, S. Jenvey, I. Cosic
To gain an understanding of the interaction between ELF electromagnetic fields produced by mobile phones and biological tissue, knowledge of the low frequency spectral characteristics of different mobile phones is required. Investigation showed that GSM and AMPS mobile phones exhibit different but distinct low frequency electromagnetic spectral components. It is speculated that these low frequency components, in particular those close to normal brain wave frequencies between 1-30 Hz may produce effects on the human EEG.
为了了解手机产生的极低频电磁场与生物组织之间的相互作用,需要了解不同手机的低频频谱特性。调查表明,GSM和AMPS手机表现出不同但明显的低频电磁频谱成分。据推测,这些低频成分,特别是那些接近正常脑电波频率在1-30赫兹之间的成分,可能会对人类脑电图产生影响。
{"title":"Investigation of analogue and digital mobile phone low frequency radiation spectrum characteristics","authors":"B. Heath, S. Jenvey, I. Cosic","doi":"10.1109/ICBEM.1998.666406","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666406","url":null,"abstract":"To gain an understanding of the interaction between ELF electromagnetic fields produced by mobile phones and biological tissue, knowledge of the low frequency spectral characteristics of different mobile phones is required. Investigation showed that GSM and AMPS mobile phones exhibit different but distinct low frequency electromagnetic spectral components. It is speculated that these low frequency components, in particular those close to normal brain wave frequencies between 1-30 Hz may produce effects on the human EEG.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125771688","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Electrochemical treatment of localized tumors with direct current 局部肿瘤的直流电化学治疗
C. Chou, N. Vora, J.R. Li, W. Wang, Y. Yen, R. Ren, J. McDougall, C. Stand, B. Zhou, L. Weiss
To develop cancer electrochemical treatment (ECT) in the United States, we have conducted basic studies and started a Phase I clinical trial. Our in vivo preliminary results indicate that ECT is effective on RIF-I mouse tumor and rat fibrosarcomas. In the in vitro study ECT clearly demonstrated dose-dependent human oral carcinoma KB cell growth inhibition by colony-forming assay. We have started an animal study to resolve the ECT methodological problems for rat breast cancer. Meanwhile, we began a clinical trial treating patients with recurrent superficial measurable malignant tumors. Our goal is to make ECT a useful alternative method for treating localized tumors.
为了在美国发展癌症电化学治疗(ECT),我们已经进行了基础研究并开始了I期临床试验。我们的体内初步结果表明ECT对RIF-I小鼠肿瘤和大鼠纤维肉瘤有效。在体外研究中,ECT通过集落形成实验清楚地证明了剂量依赖性的人口腔癌KB细胞生长抑制。我们已经开始了一项动物研究,以解决电痉挛治疗大鼠乳腺癌的方法学问题。同时,我们开始了治疗复发性浅表恶性肿瘤患者的临床试验。我们的目标是使ECT成为治疗局部肿瘤的一种有用的替代方法。
{"title":"Electrochemical treatment of localized tumors with direct current","authors":"C. Chou, N. Vora, J.R. Li, W. Wang, Y. Yen, R. Ren, J. McDougall, C. Stand, B. Zhou, L. Weiss","doi":"10.1109/ICBEM.1998.666374","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666374","url":null,"abstract":"To develop cancer electrochemical treatment (ECT) in the United States, we have conducted basic studies and started a Phase I clinical trial. Our in vivo preliminary results indicate that ECT is effective on RIF-I mouse tumor and rat fibrosarcomas. In the in vitro study ECT clearly demonstrated dose-dependent human oral carcinoma KB cell growth inhibition by colony-forming assay. We have started an animal study to resolve the ECT methodological problems for rat breast cancer. Meanwhile, we began a clinical trial treating patients with recurrent superficial measurable malignant tumors. Our goal is to make ECT a useful alternative method for treating localized tumors.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133930741","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Myocardial anisotropy in genesis of abnormal Q waves in hypertrophic cardiomyopathy: a simulation study 肥厚性心肌病异常Q波发生的心肌各向异性:模拟研究
D. Wei, N. Miyamoto, S. Mashima
Computer simulation with a whole-heart model was conducted to study genesis of abnormal Q waves in hypertrophic cardiomyopathy (HCM). The anatomic feature of HCM was modeled based on clinical echocardiogram images. Possible changes in anisotropy as well as in other electrophysiologic properties in hypertrophic tissue were simulated based on pathologic findings. Simulated ECGs showing the main features of HCM were obtained by assuming isotropic fiber orientation in hypertrophic tissue and by changing other properties from normal values. This study suggests a possible mechanism to account for abnormal Q waves in HCM.
采用全心模型进行计算机模拟,研究肥厚性心肌病(HCM)异常Q波的发生机制。根据临床超声心动图对HCM的解剖特征进行建模。根据病理结果模拟了肥厚组织各向异性和其他电生理特性的可能变化。通过假设肥厚组织中的纤维取向各向同性,并通过改变正常值的其他特性,可以获得显示HCM主要特征的模拟心电图。本研究提出了一种解释HCM异常Q波的可能机制。
{"title":"Myocardial anisotropy in genesis of abnormal Q waves in hypertrophic cardiomyopathy: a simulation study","authors":"D. Wei, N. Miyamoto, S. Mashima","doi":"10.1109/ICBEM.1998.666456","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666456","url":null,"abstract":"Computer simulation with a whole-heart model was conducted to study genesis of abnormal Q waves in hypertrophic cardiomyopathy (HCM). The anatomic feature of HCM was modeled based on clinical echocardiogram images. Possible changes in anisotropy as well as in other electrophysiologic properties in hypertrophic tissue were simulated based on pathologic findings. Simulated ECGs showing the main features of HCM were obtained by assuming isotropic fiber orientation in hypertrophic tissue and by changing other properties from normal values. This study suggests a possible mechanism to account for abnormal Q waves in HCM.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133492827","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Is accurate recording of the surface Laplacian feasible? 精确记录表面拉普拉斯是否可行?
D. Geselowitz, J. Ferrara
Experimental and model studies were performed to measure the surface Laplacian using a rectangular finite difference approximation. The experimental approach used 10 normal subjects with two sites on the torso. Electrode spacing was 2 cm. The surface Laplacian is theoretically independent of rotation of the electrode array. The data showed considerable variation with rotation. Model studies employed a realistic 23 dipole source. A spherical volume conductor showed invariance with rotation, as anticipated theoretically. A realistic torso, however, showed variation with rotation, although a not as severe as that measured. The average signal to noise ratio was 3.3 and 2.5 at the two sites. These results raise serious questions about the practical ability to measure the surface Laplacian on the torso.
实验和模型研究进行了测量表面拉普拉斯使用矩形有限差分近似。实验方法采用10名正常受试者,躯干上有两个部位。电极间距为2 cm。表面拉普拉斯量在理论上与电极阵列的旋转无关。数据显示随着旋转有相当大的变化。模型研究采用了一个现实的23偶极子源。球形体积导体表现出随旋转的不变性,正如理论上所预料的那样。然而,真实的躯干随着旋转而变化,尽管没有测量的那么严重。两个站点的平均信噪比分别为3.3和2.5。这些结果对测量躯干表面拉普拉斯函数的实际能力提出了严重的问题。
{"title":"Is accurate recording of the surface Laplacian feasible?","authors":"D. Geselowitz, J. Ferrara","doi":"10.1109/ICBEM.1998.666366","DOIUrl":"https://doi.org/10.1109/ICBEM.1998.666366","url":null,"abstract":"Experimental and model studies were performed to measure the surface Laplacian using a rectangular finite difference approximation. The experimental approach used 10 normal subjects with two sites on the torso. Electrode spacing was 2 cm. The surface Laplacian is theoretically independent of rotation of the electrode array. The data showed considerable variation with rotation. Model studies employed a realistic 23 dipole source. A spherical volume conductor showed invariance with rotation, as anticipated theoretically. A realistic torso, however, showed variation with rotation, although a not as severe as that measured. The average signal to noise ratio was 3.3 and 2.5 at the two sites. These results raise serious questions about the practical ability to measure the surface Laplacian on the torso.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128825708","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1