Effects of Instrument Transformers Connection point on Measured Impedance by Distance Relay in Presence of SSSC

A. Kazemi, S. Jamali, H. Shateri
{"title":"Effects of Instrument Transformers Connection point on Measured Impedance by Distance Relay in Presence of SSSC","authors":"A. Kazemi, S. Jamali, H. Shateri","doi":"10.1109/ICPST.2006.321902","DOIUrl":null,"url":null,"abstract":"This paper presents the measured impedance at the relaying point in the presence of a series connected flexible alternating current transmission system (FACTS) device, i.e. static synchronous series compensator (SSSC). The presence of SSSC on a transmission line has a great influence on the tripping characteristic of distance relays. Distance relay tripping characteristic itself depends on the power system structural conditions (short circuit levels at the line ends), pre-fault operational conditions (load angle and voltage magnitude ratio at the line ends), and especially the ground fault resistance. In the presence of SSSC, its controlling parameters as well as the connection point of the instrument transformers of distance relay affect the tripping characteristic. Here, the measured impedance at the relaying point is calculated due to concerning parameters.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Conference on Power System Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2006.321902","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper presents the measured impedance at the relaying point in the presence of a series connected flexible alternating current transmission system (FACTS) device, i.e. static synchronous series compensator (SSSC). The presence of SSSC on a transmission line has a great influence on the tripping characteristic of distance relays. Distance relay tripping characteristic itself depends on the power system structural conditions (short circuit levels at the line ends), pre-fault operational conditions (load angle and voltage magnitude ratio at the line ends), and especially the ground fault resistance. In the presence of SSSC, its controlling parameters as well as the connection point of the instrument transformers of distance relay affect the tripping characteristic. Here, the measured impedance at the relaying point is calculated due to concerning parameters.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SSSC存在时仪表变压器连接点对距离继电器测量阻抗的影响
本文介绍了在并联柔性交流输电系统(FACTS)装置即静态同步串联补偿器(SSSC)的情况下,继电点处的阻抗测量。传输线上SSSC的存在对距离继电器的跳闸特性有很大的影响。距离继电器跳闸特性本身取决于电力系统的结构条件(线路两端的短路程度)、故障前运行条件(线路两端的负载角度和电压幅值比),尤其是接地故障电阻。在SSSC存在的情况下,其控制参数以及距离继电器仪表变压器的连接点都会影响跳闸特性。在这里,继电点的测量阻抗是根据相关参数计算的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A New Research for Internal Fault Simulation Model of Transformer Studies on the Variable Speed Wind Turbine Control System Based on PSCAD/EMTDC Research on Dynamic Load Modeling Using Back Propagation Neural Network for Electric Power System Voltage Sensitivity Analysis in Voltage Support of the China Southern Power Grid Study on Line Detection and Fault Location with Automatic Track Arc Suppression Coil Device
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1