Determinig of autoregressive parameters from electrogastrogram signals using Cramer-Rao Lower Bound

Çiğdem Gülüzar Latifoğlu, F. Latifoğlu, Emre Çelikzencir, G. Sezgin, M. A. Yurci
{"title":"Determinig of autoregressive parameters from electrogastrogram signals using Cramer-Rao Lower Bound","authors":"Çiğdem Gülüzar Latifoğlu, F. Latifoğlu, Emre Çelikzencir, G. Sezgin, M. A. Yurci","doi":"10.1109/tiptekno.2016.7863066","DOIUrl":null,"url":null,"abstract":"Gastroparesis is a kind of stomach disease that is identified with delay of gastric emptying of solid food without mechanical obstruction. The disease is diagnosed by invasive techniques. Scintigraphy imaging technique is accepted as the gold standard in diagnosis although having many disadvantages. In this study. non invasive EGG signals were obtained from gastroparesis patients and healthy volunteers. Power Spectral Density (PSD) graphs were obtained for purpose of determining feature in frequency axis for diagnosis. PSD method for which parametric method that is used to the signals, was determined using Cramer-Rao Lower Bound (CRLB) method.","PeriodicalId":431660,"journal":{"name":"2016 Medical Technologies National Congress (TIPTEKNO)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Medical Technologies National Congress (TIPTEKNO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/tiptekno.2016.7863066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Gastroparesis is a kind of stomach disease that is identified with delay of gastric emptying of solid food without mechanical obstruction. The disease is diagnosed by invasive techniques. Scintigraphy imaging technique is accepted as the gold standard in diagnosis although having many disadvantages. In this study. non invasive EGG signals were obtained from gastroparesis patients and healthy volunteers. Power Spectral Density (PSD) graphs were obtained for purpose of determining feature in frequency axis for diagnosis. PSD method for which parametric method that is used to the signals, was determined using Cramer-Rao Lower Bound (CRLB) method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用Cramer-Rao下界确定胃电信号的自回归参数
胃轻瘫是一种以胃排空固体食物延迟而无机械性阻塞为特征的胃病。这种疾病是通过侵入性技术诊断的。闪烁成像技术虽然有许多缺点,但已被公认为诊断的金标准。在这项研究中。从胃轻瘫患者和健康志愿者中获得无创EGG信号。获得功率谱密度(PSD)图,以确定频率轴上的特征,用于诊断。采用crmer - rao下界(CRLB)方法确定了信号参数化方法的PSD方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of prosthetic hand simulator Development of clinical engineering units and evaluation of the organization in public hospitals Fractal dimension analysis of cerebellar grey matter in patients with Chiary Malformation type-I Surgical operation simulation based on virtual reality Design of coils driven by pulsed electromagnetic field generator and the effect of wound healing in rats
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1