Analysis of the magnetic field distribution of the reactor and its coupling to the shielding box under short-circuit condition of flexible DC converter station

Tilu Zhang, C. Jiao
{"title":"Analysis of the magnetic field distribution of the reactor and its coupling to the shielding box under short-circuit condition of flexible DC converter station","authors":"Tilu Zhang, C. Jiao","doi":"10.1109/CEECT55960.2022.10030639","DOIUrl":null,"url":null,"abstract":"With the rapid development of primary and secondary fusion, more and more secondary devices are installed nearby the strong magnetic field sources. In the past, secondary equipment was generally not arranged around the reactor. Nowadays, the high requirement of compact development for space utilization makes it necessary to arrange secondary equipment around the reactor. Since the reactor is a strong magnetic field source in the flexible DC converter station, especially in short circuit, the secondary equipment arranged around it is easy to be disturbed by the strong magnetic field. Thus, the magnetic field distribution of the reactor needs to be studied. The existing studies about the magnetic field distribution are mostly based on highly simplified model. The existing studies about the shielding efficiency of the shielding box are mainly carried out in the high frequency band, and based on simple geometric models. In this paper, Theoretical derivation and simulation calculation of the magnetic field distribution of the unsimplified model are completed. Furthermore, the effects of the orientation of the shielding box with complex structure on the shielding effect are studied. In particular, the frequency of the short circuit current of the reactor measured in the field is analyzed and the self-inductance and mutual inductance parameters are calculated according to the unsimplified reactor structure. The magnetic field distribution around the bipolar reactor is calculated by using Biot Savart's law under the condition of quasi-static state. In addition, the calculation model of the bipolar reactor's magnetic field and the shielding efficiency of the shielding box are established in the electromagnetic field simulation software comsol. The results show that the main frequency range of the short-circuit current is DC- 180kHz, the theoretical calculation of the magnetic field distributionof the reactor is in good agreement with the finite element simulation results, the relative error is within 5%, and the best orientation of the shielded box is that the door is perpendicular to the magnetic field. The research results can provide reference for the layout of secondary equipment and the establishment of immunity standard for protection and control equipment under the condition of short circuit fault in converter station.","PeriodicalId":187017,"journal":{"name":"2022 4th International Conference on Electrical Engineering and Control Technologies (CEECT)","volume":"122 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 4th International Conference on Electrical Engineering and Control Technologies (CEECT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEECT55960.2022.10030639","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With the rapid development of primary and secondary fusion, more and more secondary devices are installed nearby the strong magnetic field sources. In the past, secondary equipment was generally not arranged around the reactor. Nowadays, the high requirement of compact development for space utilization makes it necessary to arrange secondary equipment around the reactor. Since the reactor is a strong magnetic field source in the flexible DC converter station, especially in short circuit, the secondary equipment arranged around it is easy to be disturbed by the strong magnetic field. Thus, the magnetic field distribution of the reactor needs to be studied. The existing studies about the magnetic field distribution are mostly based on highly simplified model. The existing studies about the shielding efficiency of the shielding box are mainly carried out in the high frequency band, and based on simple geometric models. In this paper, Theoretical derivation and simulation calculation of the magnetic field distribution of the unsimplified model are completed. Furthermore, the effects of the orientation of the shielding box with complex structure on the shielding effect are studied. In particular, the frequency of the short circuit current of the reactor measured in the field is analyzed and the self-inductance and mutual inductance parameters are calculated according to the unsimplified reactor structure. The magnetic field distribution around the bipolar reactor is calculated by using Biot Savart's law under the condition of quasi-static state. In addition, the calculation model of the bipolar reactor's magnetic field and the shielding efficiency of the shielding box are established in the electromagnetic field simulation software comsol. The results show that the main frequency range of the short-circuit current is DC- 180kHz, the theoretical calculation of the magnetic field distributionof the reactor is in good agreement with the finite element simulation results, the relative error is within 5%, and the best orientation of the shielded box is that the door is perpendicular to the magnetic field. The research results can provide reference for the layout of secondary equipment and the establishment of immunity standard for protection and control equipment under the condition of short circuit fault in converter station.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
柔性直流换流站短路工况下电抗器磁场分布及其与屏蔽箱的耦合分析
随着一次和二次核聚变的迅速发展,越来越多的二次核聚变装置被安装在强磁场源附近。过去,二次设备一般不布置在反应堆周围。目前,对空间利用的要求越来越高,要求在反应器周围布置二次设备。由于电抗器在柔性直流换流站中是强磁场源,特别是在短路情况下,其周围布置的二次设备容易受到强磁场的干扰。因此,需要对反应器的磁场分布进行研究。现有的磁场分布研究大多基于高度简化的模型。现有的屏蔽盒屏蔽效率的研究主要是在高频段进行的,并且基于简单的几何模型。本文对未简化模型的磁场分布进行了理论推导和仿真计算。此外,还研究了复杂结构屏蔽盒的方位对屏蔽效果的影响。特别分析了现场测量电抗器短路电流的频率,并根据未简化的电抗器结构计算了电抗器的自感和互感参数。在准静态条件下,利用Biot Savart定律计算了双极反应器周围的磁场分布。此外,在电磁场仿真软件comsol中建立了双极电抗器磁场和屏蔽箱屏蔽效率的计算模型。结果表明,短路电流的主要频率范围为DC- 180kHz,电抗器磁场分布的理论计算与有限元仿真结果吻合较好,相对误差在5%以内,屏蔽箱的最佳方位为门与磁场垂直。研究结果可为换流站短路故障情况下二次设备的布置和保护控制设备抗扰度标准的制定提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An optimization model based interval power flow analysis method considering the tracking characteristic of static voltage generator Design of Liquid Level Monitoring and Alarm System in Transformer Accident Oil Pool Mechanism Analysis of the SSR Suppression in DFIG-Based Wind farm Systems with SVCs Evaluation Method of Aging State of Oil-Paper Insulation Based on Time Domain Dielectric Response Study on the Effect of Multi-circuit Laying on Ampacity of Low Smoke Halogen-free Cable
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1