An Improved DC-Link Voltage Control Strategy of SAPF under Unbalanced Loads

Maoning Xu, Li Peng, Xuefeng Wang
{"title":"An Improved DC-Link Voltage Control Strategy of SAPF under Unbalanced Loads","authors":"Maoning Xu, Li Peng, Xuefeng Wang","doi":"10.1145/3429536.3429541","DOIUrl":null,"url":null,"abstract":"The shunt active power filter (SAPF) based on three-leg voltage source converter is widely used to compensate the harmonic currents caused by nonlinear loads of grid. However, when the nonlinear loads are unbalanced, the grid currents compensated by SAPF are still unbalanced and distorted even an accurate current detection method is adopted. The reason is that when SAPF compensates the unbalanced loads of grid, the DC-link voltage will contain the second-order harmonic which has influence on the d-axis reference of SAPF's current control loop. Then the output of the SAPF will contain extra third-order harmonic and fundamental negative sequence currents, which make grid currents distorted and unbalanced. In this paper, in order to overcome the problem of poor filtering and dynamic performance by using traditional PI control for DC-link voltage, a MAF-PI controller which combines a moving average filter (MAF), a phase-lead compensator (PLC) and a PI control into DC-link voltage control loop is proposed. This strategy realizes the accurate harmonic currents compensation and excellent DC-link voltage dynamic response of SAPF for unbalanced loads. The effectiveness of the proposed strategy is verified through simulation results.","PeriodicalId":309998,"journal":{"name":"Proceedings of the 2020 3rd International Conference on Electronics and Electrical Engineering Technology","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2020 3rd International Conference on Electronics and Electrical Engineering Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3429536.3429541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The shunt active power filter (SAPF) based on three-leg voltage source converter is widely used to compensate the harmonic currents caused by nonlinear loads of grid. However, when the nonlinear loads are unbalanced, the grid currents compensated by SAPF are still unbalanced and distorted even an accurate current detection method is adopted. The reason is that when SAPF compensates the unbalanced loads of grid, the DC-link voltage will contain the second-order harmonic which has influence on the d-axis reference of SAPF's current control loop. Then the output of the SAPF will contain extra third-order harmonic and fundamental negative sequence currents, which make grid currents distorted and unbalanced. In this paper, in order to overcome the problem of poor filtering and dynamic performance by using traditional PI control for DC-link voltage, a MAF-PI controller which combines a moving average filter (MAF), a phase-lead compensator (PLC) and a PI control into DC-link voltage control loop is proposed. This strategy realizes the accurate harmonic currents compensation and excellent DC-link voltage dynamic response of SAPF for unbalanced loads. The effectiveness of the proposed strategy is verified through simulation results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不平衡负载下改进的SAPF直流电压控制策略
基于三支路电压源变换器的并联有源电力滤波器(SAPF)被广泛用于补偿电网中非线性负荷引起的谐波电流。然而,当非线性负载不平衡时,即使采用精确的电流检测方法,经SAPF补偿的电网电流仍然是不平衡和畸变的。这是因为当SAPF对电网的不平衡负载进行补偿时,直流电压中会含有二阶谐波,对SAPF电流控制环的d轴基准有影响。那么SAPF的输出将包含额外的三阶谐波和基波负序电流,使电网电流失真和不平衡。为了克服传统PI控制直流电压滤波效果差和动态性能差的问题,提出了一种将移动平均滤波器(MAF)、超前相补偿器(PLC)和PI控制集成到直流电压控制回路中的MAF-PI控制器。该策略实现了对不平衡负载精确的谐波电流补偿和良好的直流电压动态响应。仿真结果验证了所提策略的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of Loading Direction on the Mechanical Responses of Transmission Tower Design and Implementation of an Automatic Coffee Dryer Proceedings of the 2020 3rd International Conference on Electronics and Electrical Engineering Technology An Improved DC-Link Voltage Control Strategy of SAPF under Unbalanced Loads A Study on Real-Time Modification of the Refractive Index of A Surrounding Medium using a Uniform Microsphere In Digital Holographic Microscopy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1