G. T. de Paula, J. R. B. de A. Monteiro, T. E. P. de Almeida, M. P. de Santana, W. C. A. Pereira, C. Oliveira
{"title":"Evaluation of surface mounted PM machine's parameters on load conditions using frozen permeability method. Part. II","authors":"G. T. de Paula, J. R. B. de A. Monteiro, T. E. P. de Almeida, M. P. de Santana, W. C. A. Pereira, C. Oliveira","doi":"10.1109/ICELMACH.2014.6960174","DOIUrl":null,"url":null,"abstract":"This work deals with the influence of magnetic saturation on machine parameters of a surface mounted permanent magnet synchronous machine driven by an ideal six-step three-phase inverter. In this second part, a special attention is given to back-EMF calculation since the linkage flux of each phase has an abrupt change every sixty electrical degree due to the phase commutation.","PeriodicalId":288960,"journal":{"name":"2014 International Conference on Electrical Machines (ICEM)","volume":"233 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Electrical Machines (ICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2014.6960174","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
This work deals with the influence of magnetic saturation on machine parameters of a surface mounted permanent magnet synchronous machine driven by an ideal six-step three-phase inverter. In this second part, a special attention is given to back-EMF calculation since the linkage flux of each phase has an abrupt change every sixty electrical degree due to the phase commutation.