Inrush current requirements analysis for FAA facility power systems

Y.C. Hubbel, C. Sweetra
{"title":"Inrush current requirements analysis for FAA facility power systems","authors":"Y.C. Hubbel, C. Sweetra","doi":"10.1109/IAS.1993.299231","DOIUrl":null,"url":null,"abstract":"Martin Marietta Corporation was tasked to perform an analysis of developing a new inrush current requirement which will be cost-effective and technically acceptable for facility power system stability and which can be met by adequately designed electrical/electronic equipment. This analysis of an allowable inrush current is based on the characteristics of the facility branch circuit breakers which provide power to subsystems on the critical bus. A recommendation is made and an inrush current requirements curve is developed to replace the existing limits stated in FAA Order 6950.2c and FAA G 2100e. The curve identifies a range of inrush limits to be imposed by comparing the amount of inrush a system is allowed to produce versus the length of time a system should be required to return to within 110% of the normal steady-state condition. Requirements developed from the curve are based on individual system measurements (shorter duration requirements) as well as facility circuit breaker characteristics (longer duration requirements). Systems falling between these limits may not exceed the requirement identified at the curve. As a result, a significant FAA cost avoidance can be realized when special soft-start devices are not needed for all equipment, thus allowing greater use of commercial-off-the-shelf equipment.<<ETX>>","PeriodicalId":345027,"journal":{"name":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1993.299231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Martin Marietta Corporation was tasked to perform an analysis of developing a new inrush current requirement which will be cost-effective and technically acceptable for facility power system stability and which can be met by adequately designed electrical/electronic equipment. This analysis of an allowable inrush current is based on the characteristics of the facility branch circuit breakers which provide power to subsystems on the critical bus. A recommendation is made and an inrush current requirements curve is developed to replace the existing limits stated in FAA Order 6950.2c and FAA G 2100e. The curve identifies a range of inrush limits to be imposed by comparing the amount of inrush a system is allowed to produce versus the length of time a system should be required to return to within 110% of the normal steady-state condition. Requirements developed from the curve are based on individual system measurements (shorter duration requirements) as well as facility circuit breaker characteristics (longer duration requirements). Systems falling between these limits may not exceed the requirement identified at the curve. As a result, a significant FAA cost avoidance can be realized when special soft-start devices are not needed for all equipment, thus allowing greater use of commercial-off-the-shelf equipment.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
FAA设施电力系统的涌流需求分析
Martin Marietta公司的任务是对开发新的涌流要求进行分析,该要求将具有成本效益和技术上可接受的设施电力系统稳定性,并且可以通过适当设计的电气/电子设备来满足。这种允许浪涌电流的分析是基于向关键母线上的子系统供电的设施分支断路器的特性。提出了一项建议,并制定了涌流需求曲线,以取代FAA命令6950.2c和FAA G 2100e中规定的现有限制。该曲线通过比较系统允许产生的涌流量与系统应要求恢复到正常稳态条件110%以内的时间长度来确定要施加的涌流限制范围。从曲线中开发的要求基于单个系统测量(较短持续时间要求)以及设施断路器特性(较长持续时间要求)。处于这些限制之间的系统可能不会超过曲线上确定的需求。因此,当所有设备都不需要特殊的软启动设备时,可以实现显著的FAA成本规避,从而允许更多地使用商用现货设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Maximum torque control of an induction machine in the field weakening region Production of O/W type uniformly sized droplets using a convergent AC electric field The effect of temperature on starting and stabilization of compact fluorescent systems A low cost compact CCD grating spectrometer Surface handling effects of fabricating thin dielectric film HDPE on TSDC analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1