Rate-dependent hysteresis in the EMG-force relationship: A new discovery in EMG-force relationship

Lizhi Pan, Dingguo Zhang, X. Sheng, Xiangyang Zhu
{"title":"Rate-dependent hysteresis in the EMG-force relationship: A new discovery in EMG-force relationship","authors":"Lizhi Pan, Dingguo Zhang, X. Sheng, Xiangyang Zhu","doi":"10.1109/NER.2015.7146749","DOIUrl":null,"url":null,"abstract":"In this study, we analyzed the existence of rate-dependent hysteresis in the electromyography (EMG)-force relationship. Eight able-bodied subjects participated in the experiment. Surface EMG signals were acquired from flexor pollicis longus muscle from 0% to 100% maximum voluntary contraction (MVC). The subject was asked to gradually increase grasping force from 0% to 100% MVC and decrease grasping force from 100% to 0% MVC at five different frequencies (1.5, 1, 0.5, 0.25 and 0.125 Hz). Mean absolute value (MAV) was chosen to represent the EMG signals and force signals. In order to compare differences in force between contraction and relaxation periods to EMG activity among different frequency conditions, a hysteresis index (HI), defined as an area inside the hysteresis cycle, was adopted. The results showed that all mean values of HI in different frequency conditions were larger than 0, which proved that hysteresis cycles existed in all frequency conditions. The results also showed that the HI values in different frequency conditions were significantly different from each other (p <; 0.005), which proved hysteresis effects in EMG-force relationship were rate-dependent. The rate-dependent hysteresis in EMG-force relationship has a huge potential to improve the estimation performance of grasping force from EMG.","PeriodicalId":137451,"journal":{"name":"2015 7th International IEEE/EMBS Conference on Neural Engineering (NER)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 7th International IEEE/EMBS Conference on Neural Engineering (NER)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NER.2015.7146749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

In this study, we analyzed the existence of rate-dependent hysteresis in the electromyography (EMG)-force relationship. Eight able-bodied subjects participated in the experiment. Surface EMG signals were acquired from flexor pollicis longus muscle from 0% to 100% maximum voluntary contraction (MVC). The subject was asked to gradually increase grasping force from 0% to 100% MVC and decrease grasping force from 100% to 0% MVC at five different frequencies (1.5, 1, 0.5, 0.25 and 0.125 Hz). Mean absolute value (MAV) was chosen to represent the EMG signals and force signals. In order to compare differences in force between contraction and relaxation periods to EMG activity among different frequency conditions, a hysteresis index (HI), defined as an area inside the hysteresis cycle, was adopted. The results showed that all mean values of HI in different frequency conditions were larger than 0, which proved that hysteresis cycles existed in all frequency conditions. The results also showed that the HI values in different frequency conditions were significantly different from each other (p <; 0.005), which proved hysteresis effects in EMG-force relationship were rate-dependent. The rate-dependent hysteresis in EMG-force relationship has a huge potential to improve the estimation performance of grasping force from EMG.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肌电-力关系中速率相关的迟滞:肌电-力关系的新发现
在这项研究中,我们分析了肌电图(EMG)-力关系中存在的速率依赖性滞后。8名身体健全的受试者参加了实验。在0%至100%最大自愿收缩(MVC)时,从拇长屈肌获得表面肌电信号。在5个不同频率(1.5、1、0.5、0.25和0.125 Hz)下,受试者从0% MVC逐渐增加抓握力到100% MVC,从100% MVC逐渐减少抓握力。选取平均绝对值(Mean absolute value, MAV)表示肌电信号和力信号。为了比较不同频率条件下收缩和松弛期对肌电活动的作用力差异,采用迟滞指数(HI),定义为迟滞周期内的面积。结果表明,不同频率条件下的HI均值均大于0,证明在所有频率条件下均存在滞回周期。结果还表明,不同频率条件下的HI值存在显著差异(p <;0.005),证明肌电-力关系中的迟滞效应是率相关的。肌电-力关系中与速率相关的滞后对提高肌电抓取力的估计性能具有巨大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
iNODE in-vivo testing for selective vagus nerve recording and stimulation Computational studies on urinary bladder smooth muscle: Modeling ion channels and their role in generating electrical activity Fast calibration of a thirteen-command BCI by simulating SSVEPs from trains of transient VEPs - towards time-domain SSVEP BCI paradigms A hybrid NMES-exoskeleton for real objects interaction Computationally efficient, configurable, causal, real-time phase detection applied to local field potential oscillations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1