Ultrasound intensity calculations for a vessel with simulated wall lesion

R.S. Thompson, C. Macaskill, L. Farnell, W. Fraser
{"title":"Ultrasound intensity calculations for a vessel with simulated wall lesion","authors":"R.S. Thompson, C. Macaskill, L. Farnell, W. Fraser","doi":"10.1109/ULTSYM.2002.1192648","DOIUrl":null,"url":null,"abstract":"Vascular disease alters the shape of the lumen of a blood vessel. The lumen is not circular from the early stages of the disease, where there is intimal thickening, through to advanced stages where a large plaque may protrude into the lumen. Using a mathematical model we investigated the ultrasound intensity distribution, both within the vessel wall and across the lumen, in the presence of a simulated wall lesion. Acoustic impedance interfaces due to wall lesions have dimensions (typically /spl sim/ 1 mm) only slightly greater than the wavelength (/spl sim/ 0.3 mm for 5 MHz ultrasound). Full wave solutions for the acoustic field are therefore required. Exact solutions in terms of Bessel functions are known for the case of a cylindrical vessel, and a collocation method based on this was developed for non-circular interfaces. By considering two such interfaces we developed a novel model representation of a vessel with a simulated wall lesion. The results of this study show how vessel wall properties may alter the ultrasound intensity distribution within the vessel wall and across the lumen. In the case of non-circular impedance interfaces there can be significant effects due to the local curvature and orientation of the interface.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1192648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Vascular disease alters the shape of the lumen of a blood vessel. The lumen is not circular from the early stages of the disease, where there is intimal thickening, through to advanced stages where a large plaque may protrude into the lumen. Using a mathematical model we investigated the ultrasound intensity distribution, both within the vessel wall and across the lumen, in the presence of a simulated wall lesion. Acoustic impedance interfaces due to wall lesions have dimensions (typically /spl sim/ 1 mm) only slightly greater than the wavelength (/spl sim/ 0.3 mm for 5 MHz ultrasound). Full wave solutions for the acoustic field are therefore required. Exact solutions in terms of Bessel functions are known for the case of a cylindrical vessel, and a collocation method based on this was developed for non-circular interfaces. By considering two such interfaces we developed a novel model representation of a vessel with a simulated wall lesion. The results of this study show how vessel wall properties may alter the ultrasound intensity distribution within the vessel wall and across the lumen. In the case of non-circular impedance interfaces there can be significant effects due to the local curvature and orientation of the interface.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
模拟血管壁病变的超声强度计算
血管疾病会改变血管腔的形状。从疾病的早期(内膜增厚)到晚期(大斑块可能突出到管腔),管腔不是圆形的。利用数学模型,我们研究了超声强度分布,既在血管壁内,也在管腔内,在模拟壁病变的存在。由于壁损伤引起的声阻抗界面的尺寸(通常为/spl sim/ 1mm)仅略大于波长(5mhz超声为/spl sim/ 0.3 mm)。因此需要声场的全波解。在圆柱形容器的情况下,贝塞尔函数的精确解是已知的,并且基于此开发了非圆形界面的配置方法。通过考虑两个这样的界面,我们开发了一个具有模拟壁病变的血管的新模型表示。本研究结果显示了血管壁特性如何改变血管壁内和管腔内的超声强度分布。在非圆形阻抗界面的情况下,由于界面的局部曲率和方向,可能会产生显著的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of transducers arrays from piezoelectric hollow spheres Non-cylindrical transmission focusing for large depth of field Detection and mapping of thermal lesions using dual-mode ultrasound phased arrays Layered manufacturing for prototyping of novel transducers The effect of microbubble concentration on thresholds for tissue damage produced by single bursts of high intensity ultrasound during continuous Optison/spl reg/ infusion
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1