Modelling the motion dependent point spread function in motion corrected small animal PET imaging

G. Angelis, J. Gillam, A. Kyme, R. Fulton, S. Meikle
{"title":"Modelling the motion dependent point spread function in motion corrected small animal PET imaging","authors":"G. Angelis, J. Gillam, A. Kyme, R. Fulton, S. Meikle","doi":"10.1109/NSSMIC.2016.8069389","DOIUrl":null,"url":null,"abstract":"Motion corrected images from awake and freely moving animals often exhibit reduced resolution when compared to their stationary counterparts. This could be attributed to the combination of brief periods of fast animal motion and insufficient motion sampling speed. In this paper we hypothesise that we can measure the motion dependent point spread function of a given study and mitigate the motion blurring artifacts in the reconstructed images, in a similar way that a measured system response point spread function can improve resolution due to geometric effects (e.g. parallax errors). We investigated this hypothesis on a set of experimentally measured phantom data, which underwent a series of distinctively different motion patterns, ranging from slow to fast. Preliminary results showed that motion corrected images have reduced resolution compared to the stationary image and noticeable motion blurring artefacts, particularly for fast speed/acceleration settings. In addition, images deconvolved after reconstruction with the measured motion dependent PSF appear to be sharper compared to their unprocessed counterparts, yet without completely eliminating the motion blurring artefacts. Work is in progress to refine the methodology, by decomposing the geometric and motion components of the PSF, as well as including the deconvolution within the reconstruction algorithm.","PeriodicalId":184587,"journal":{"name":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2016.8069389","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Motion corrected images from awake and freely moving animals often exhibit reduced resolution when compared to their stationary counterparts. This could be attributed to the combination of brief periods of fast animal motion and insufficient motion sampling speed. In this paper we hypothesise that we can measure the motion dependent point spread function of a given study and mitigate the motion blurring artifacts in the reconstructed images, in a similar way that a measured system response point spread function can improve resolution due to geometric effects (e.g. parallax errors). We investigated this hypothesis on a set of experimentally measured phantom data, which underwent a series of distinctively different motion patterns, ranging from slow to fast. Preliminary results showed that motion corrected images have reduced resolution compared to the stationary image and noticeable motion blurring artefacts, particularly for fast speed/acceleration settings. In addition, images deconvolved after reconstruction with the measured motion dependent PSF appear to be sharper compared to their unprocessed counterparts, yet without completely eliminating the motion blurring artefacts. Work is in progress to refine the methodology, by decomposing the geometric and motion components of the PSF, as well as including the deconvolution within the reconstruction algorithm.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
运动校正小动物PET成像中运动相关点扩展函数的建模
运动校正图像从清醒和自由运动的动物往往表现出较低的分辨率相比,他们的静止对手。这可能是由于动物快速运动的短时间和运动采样速度不足的结合。在本文中,我们假设我们可以测量给定研究的运动相关点扩展函数并减轻重建图像中的运动模糊伪影,以类似的方式测量系统响应点扩展函数可以提高由于几何效应(例如视差误差)而导致的分辨率。我们在一组实验测量的幻影数据上研究了这一假设,这些数据经历了一系列明显不同的运动模式,从慢到快。初步结果表明,与静止图像和明显的运动模糊伪影相比,运动校正图像的分辨率降低了,特别是在快速/加速设置下。此外,与未处理的图像相比,使用测量的运动相关PSF重建后的图像反卷积似乎更清晰,但没有完全消除运动模糊伪影。通过分解PSF的几何和运动分量,以及在重建算法中加入反卷积,改进方法的工作正在进行中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of flexible, scalable, low cost readout for beam tests of the high granularity calorimeter for the CMS endcap Latest frontier technology and design of the ATLAS calorimeter trigger board dedicated to jet identification for the LHC run 3 The ATLAS tile calorimeter DCS for run 2 The phase-II ATLAS pixel tracker upgrade: Layout and mechanics Null-hypothesis testing using distance metrics for verification of arms-control treaties
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1