{"title":"GATE simulation of a high-performance stationary SPECT system for cardiac imaging","authors":"Dilber Uzun-Özşahin, L. Bläckberg, N. Moghadam, G. Fakhri, H. Sabet","doi":"10.1109/NSSMIC.2016.8069814","DOIUrl":null,"url":null,"abstract":"In this work we report on GATE simulation studies of DC-SPECT, a body contouring system designed for cardiac imaging applications. The design concept of the DC-SPECT is based on multiple simultaneous view of the heart enabled by the use of laser processed CsI:Tl detector modules with high intrinsic detector resolution. Our theoretical and GATE simulation results show that we can obtain ∼0.081% system sensitivity and ∼10.0 mm FWHM system spatial resolution without point spread function (PSF) modeling or other correction techniques. Image reconstruction of a Derenzo-like phantom suggest that the DC-SPECT system can resolve activity rods smaller than 10 mm diameter with no correction techniques applied.","PeriodicalId":184587,"journal":{"name":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2016.8069814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

In this work we report on GATE simulation studies of DC-SPECT, a body contouring system designed for cardiac imaging applications. The design concept of the DC-SPECT is based on multiple simultaneous view of the heart enabled by the use of laser processed CsI:Tl detector modules with high intrinsic detector resolution. Our theoretical and GATE simulation results show that we can obtain ∼0.081% system sensitivity and ∼10.0 mm FWHM system spatial resolution without point spread function (PSF) modeling or other correction techniques. Image reconstruction of a Derenzo-like phantom suggest that the DC-SPECT system can resolve activity rods smaller than 10 mm diameter with no correction techniques applied.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于心脏成像的高性能固定SPECT系统的GATE模拟
在这项工作中,我们报告了DC-SPECT的GATE模拟研究,这是一种为心脏成像应用而设计的身体轮廓系统。DC-SPECT的设计理念是基于心脏的多个同时视图,通过使用具有高内在探测器分辨率的激光处理CsI:Tl探测器模块实现。我们的理论和GATE仿真结果表明,在没有点扩散函数(PSF)建模或其他校正技术的情况下,我们可以获得~ 0.081%的系统灵敏度和~ 10.0 mm FWHM系统空间分辨率。derenzo样幻像的图像重建表明,DC-SPECT系统可以在不使用校正技术的情况下分辨直径小于10毫米的活动棒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of flexible, scalable, low cost readout for beam tests of the high granularity calorimeter for the CMS endcap Latest frontier technology and design of the ATLAS calorimeter trigger board dedicated to jet identification for the LHC run 3 The ATLAS tile calorimeter DCS for run 2 The phase-II ATLAS pixel tracker upgrade: Layout and mechanics Null-hypothesis testing using distance metrics for verification of arms-control treaties
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1