{"title":"A 50kS/s 10bit Micropower Current S/H Cell for Weak Current Bio-medical Applications","authors":"Ka Leong Tsang, Jie Yuan","doi":"10.1109/BIOCAS.2007.4463331","DOIUrl":null,"url":null,"abstract":"In this paper, a micropower current sample- and-hold front-end is designed for weak current bio-medical applications in a 0.35-mum standard CMOS process. The design reduces the distortion of the current-mode sample-and-hold stage by exploiting the exponential I-V relationship of weakly-inverted MOS transistors. The design and optimization process for the stage is introduced in the paper. With the optimized design, SPICE simulation shows that the sample-and-hold stage can achieve over 60 dB SNDR at the sampling rate of 50 kS/s, with the input signal at the Nyquist frequency of 24 kHz. The input current range is 100 nA. The power consumption of the stage is about 3.6 muW.","PeriodicalId":273819,"journal":{"name":"2007 IEEE Biomedical Circuits and Systems Conference","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Biomedical Circuits and Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2007.4463331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper, a micropower current sample- and-hold front-end is designed for weak current bio-medical applications in a 0.35-mum standard CMOS process. The design reduces the distortion of the current-mode sample-and-hold stage by exploiting the exponential I-V relationship of weakly-inverted MOS transistors. The design and optimization process for the stage is introduced in the paper. With the optimized design, SPICE simulation shows that the sample-and-hold stage can achieve over 60 dB SNDR at the sampling rate of 50 kS/s, with the input signal at the Nyquist frequency of 24 kHz. The input current range is 100 nA. The power consumption of the stage is about 3.6 muW.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
弱电流生物医学用50kS/s 10bit微功率电流s /H电池
本文采用0.35 μ m标准CMOS工艺,设计了一种用于弱电生物医学应用的微功率电流采样保持前端。该设计利用弱倒转MOS晶体管的指数I-V关系,降低了电流模式采样保持级的畸变。本文介绍了该台阶的设计与优化过程。经过优化设计,SPICE仿真表明,在采样速率为50 kS/s,输入信号为24 kHz的奈奎斯特频率下,采样保持级可以实现60 dB以上的SNDR。输入电流范围为100na。舞台功耗约3.6 muW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Breast Lesions Classification Using Modified Non-Recursive Discrete Biorthogonal Wavelet Transform Efficient Computation of the LF/HF Ratio in Heart Rate Variability Analysis Based on Bitstream Filtering On the Swept-threshold Sampling in UWB Medical Radar Long-term monitoring of electrochemical parameters from stimulated neural tissues A Mixed-Signal Multi-Chip Neural Recording Interface with Bandwidth Reduction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1