Comparative Analysis of the Digital Measurement Methods of Active Power with the Application of Approximation Polynomials

Igor V. Levashov, A. Shatokhin, A. Serov
{"title":"Comparative Analysis of the Digital Measurement Methods of Active Power with the Application of Approximation Polynomials","authors":"Igor V. Levashov, A. Shatokhin, A. Serov","doi":"10.1109/UralCon49858.2020.9216251","DOIUrl":null,"url":null,"abstract":"In this article, a comparative analysis of digital methods for the measurement of active power with the application of approximation polynomials is performed. Zero-order and first-order polynomials are considered. For each of the applied approximating polynomials, a measurement algorithm is proposed; the methodological error for the case of sinusoidal current and voltage is analyzed; recommendations to reduce the measurement error have been developed. Analytical relations are obtained allows to choose the values of the sampling frequency and the measurement time. It is shown that approximation by zero-order polynomials is much more efficient than approximation by first-order polynomials. For the case of applying the approximation polynomial of the zero-order, the methods for reducing the methodological measurement error are proposed. These methods are based on the adjustment of the number of averaged samples, the adjustment of the initial phase of the signal and the combined adjustment of the number of averaged samples and the value of the initial phase (combined technique). To apply the proposed methods, an additional measurement frequency converter is required. The reliability of the analytical relationships is confirmed by the coincidence of the analytical results and the results of simulation modeling at control points. By using software package Simulink, simulation modeling was performed to evaluate the effectiveness of the considered methods for the active power measurement.","PeriodicalId":230353,"journal":{"name":"2020 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"123 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Ural Conference on Electrical Power Engineering (UralCon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UralCon49858.2020.9216251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this article, a comparative analysis of digital methods for the measurement of active power with the application of approximation polynomials is performed. Zero-order and first-order polynomials are considered. For each of the applied approximating polynomials, a measurement algorithm is proposed; the methodological error for the case of sinusoidal current and voltage is analyzed; recommendations to reduce the measurement error have been developed. Analytical relations are obtained allows to choose the values of the sampling frequency and the measurement time. It is shown that approximation by zero-order polynomials is much more efficient than approximation by first-order polynomials. For the case of applying the approximation polynomial of the zero-order, the methods for reducing the methodological measurement error are proposed. These methods are based on the adjustment of the number of averaged samples, the adjustment of the initial phase of the signal and the combined adjustment of the number of averaged samples and the value of the initial phase (combined technique). To apply the proposed methods, an additional measurement frequency converter is required. The reliability of the analytical relationships is confirmed by the coincidence of the analytical results and the results of simulation modeling at control points. By using software package Simulink, simulation modeling was performed to evaluate the effectiveness of the considered methods for the active power measurement.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
有功功率数字测量方法与近似多项式应用的比较分析
本文对数字有功功率测量方法与近似多项式的应用进行了比较分析。零阶和一阶多项式被考虑。对于每一个应用的近似多项式,提出了一种测量算法;分析了正弦电流和正弦电压情况下的方法误差;已经提出了减少测量误差的建议。得到了可以选择采样频率和测量时间的解析关系。结果表明,用零阶多项式近似比用一阶多项式近似更有效。针对采用零阶近似多项式的情况,提出了减小方法学测量误差的方法。这些方法是基于平均样本数的调整、信号初始相位的调整以及平均样本数与初始相位值的组合调整(组合技术)。为了应用所提出的方法,需要一个额外的测量变频器。分析结果与控制点仿真建模结果吻合,证实了分析关系的可靠性。利用Simulink软件进行仿真建模,对所考虑的有功功率测量方法的有效性进行了评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of Statistical Information for Data Trend Forecasting Analysis of Power Oscillations Parameters in Autonomous Electrical Complexes Using the Method of Customization Charts Designing System for Cleaning the Surface of Solar Modules from Dust Pollution Analysis of Power Quality and Pumping Units Operation's Optimization Device for Data Communication along Power Lines
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1