Contactless and Cuffless Monitoring of Blood Pressure on a Chair Using E-Textile Materials

K. Wu, C. Chan, Yuan-ting Zhang
{"title":"Contactless and Cuffless Monitoring of Blood Pressure on a Chair Using E-Textile Materials","authors":"K. Wu, C. Chan, Yuan-ting Zhang","doi":"10.1109/ISSMDBS.2006.360107","DOIUrl":null,"url":null,"abstract":"Blood pressure (BP) can be measured cufflessly and noninvasively by using pulse transit time, which is obtained from simultaneously recorded electrocardiogram (ECG) and photoplethysmogram (PPG). To apply this BP monitoring technique in daily life, an office chair was modified into a contactless and cuffless BP-monitoring device using e-textile materials. In this study, twelve normotensive subjects, including 6 males and 6 females, were recruited for testing this BP-monitoring chair. During the experiment, exercise was carried out to obtain a wider range of BP. In total, 62 pairs of systolic BP (SBP) and diastolic BP (DBP) estimations were made. Readings from a clinically approved cuff-based automatic BP monitor was used as reference. The results showed that the estimated SBP and DBP differed from their references by -6.3plusmn10.5 mmHg and -0.7plusmn4.9 mmHg respectively. It was found that the SBP estimation errors mainly came from the data obtained immediately after exercise. Further improvement should be made to minimize those errors. However, this concept is potentially useful in self BP monitoring for home healthcare.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSMDBS.2006.360107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

Abstract

Blood pressure (BP) can be measured cufflessly and noninvasively by using pulse transit time, which is obtained from simultaneously recorded electrocardiogram (ECG) and photoplethysmogram (PPG). To apply this BP monitoring technique in daily life, an office chair was modified into a contactless and cuffless BP-monitoring device using e-textile materials. In this study, twelve normotensive subjects, including 6 males and 6 females, were recruited for testing this BP-monitoring chair. During the experiment, exercise was carried out to obtain a wider range of BP. In total, 62 pairs of systolic BP (SBP) and diastolic BP (DBP) estimations were made. Readings from a clinically approved cuff-based automatic BP monitor was used as reference. The results showed that the estimated SBP and DBP differed from their references by -6.3plusmn10.5 mmHg and -0.7plusmn4.9 mmHg respectively. It was found that the SBP estimation errors mainly came from the data obtained immediately after exercise. Further improvement should be made to minimize those errors. However, this concept is potentially useful in self BP monitoring for home healthcare.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用电子纺织材料的椅子上的非接触式和无袖带血压监测
通过同时记录心电图(ECG)和光容积描记图(PPG)获得的脉冲传递时间,可以无袖无创地测量血压(BP)。为了将这种血压监测技术应用到日常生活中,利用电子纺织材料将办公椅改造成一种非接触式、无袖扣的血压监测装置。本研究共招募了12名血压正常的受试者,其中男6名,女6名。在实验过程中,为了获得更大的血压范围,我们进行了运动。共进行了62对收缩压(SBP)和舒张压(DBP)估计。临床认可的袖带式自动血压监测仪的读数作为参考。结果表明,估计的收缩压和舒张压分别与参考文献相差-6.3plusmn10.5 mmHg和-0.7plusmn4.9 mmHg。结果发现,收缩压估计误差主要来自于运动后立即获得的数据。应进一步改进以尽量减少这些错误。然而,这个概念在家庭医疗保健的自我血压监测中是潜在的有用的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Broad Range of New Clinical Applications for a Magnetic Sensor Measuring Distance on the Human Body Applications of a Textile-Based Wearable System in clinics, exercise and under gravitational stress Using the Surgery Suturing Progress Consequences to Design a Minimally Invasive Suturing Device Virtual apparatus to study the subjective visual vertical Estimation of sleeping posture for M-Health by a wearable tri-axis accelerometer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1