High Space-Resolutive Evaluation of Subsurface Stress Distribution by Strain Scanning Method with Analyzer Using High-Energy Synchrotron X-Rays ∗

T. Shobu, J. Mizuki, Kenji Suzuki, Y. Akiniwa, Keisuke Tanaka
{"title":"High Space-Resolutive Evaluation of Subsurface Stress Distribution by Strain Scanning Method with Analyzer Using High-Energy Synchrotron X-Rays ∗","authors":"T. Shobu, J. Mizuki, Kenji Suzuki, Y. Akiniwa, Keisuke Tanaka","doi":"10.1299/JSMEA.49.376","DOIUrl":null,"url":null,"abstract":"The surface aberration effect in the strain scanning method with a Ge analyzer was examined using high- energy X-rays from the undulator synchrotron source. The synchrotron X-rays from the undulator source had an enough intensity for the strain scanning method using a goniometer with the analyzer. The use of a Ge (111) analyzer showed remarkable reduction of the surface aberration effect. However, there still existed the surface aberration for the very-near surface region from the surface to the depth of 50µm. A correction method was proposed by taking into account of the effects of the divergence of the Ge analyzer, the mis-setting of the analyzer and the X-ray attenuation. The proposed correction method was very useful for eliminating the surface aberration effect. The correction method enables a high space-resolutive evaluation of the subsurface stress distribution. The method was successfully applied to the determination of the residual stress distribution of the shot-peened steel. A precise d0 value of the strain-free lattice spacing necessary was determined from the surface stress measured by the conventional sin2ψ method using Cr-Kα radiation.","PeriodicalId":170519,"journal":{"name":"Jsme International Journal Series A-solid Mechanics and Material Engineering","volume":"89 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jsme International Journal Series A-solid Mechanics and Material Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1299/JSMEA.49.376","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The surface aberration effect in the strain scanning method with a Ge analyzer was examined using high- energy X-rays from the undulator synchrotron source. The synchrotron X-rays from the undulator source had an enough intensity for the strain scanning method using a goniometer with the analyzer. The use of a Ge (111) analyzer showed remarkable reduction of the surface aberration effect. However, there still existed the surface aberration for the very-near surface region from the surface to the depth of 50µm. A correction method was proposed by taking into account of the effects of the divergence of the Ge analyzer, the mis-setting of the analyzer and the X-ray attenuation. The proposed correction method was very useful for eliminating the surface aberration effect. The correction method enables a high space-resolutive evaluation of the subsurface stress distribution. The method was successfully applied to the determination of the residual stress distribution of the shot-peened steel. A precise d0 value of the strain-free lattice spacing necessary was determined from the surface stress measured by the conventional sin2ψ method using Cr-Kα radiation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用高能同步x射线分析仪应变扫描法评估地下应力分布的高空间分辨率
利用波动同步加速器源的高能x射线,研究了锗分析仪应变扫描法中的表面像差效应。来自波动源的同步加速器x射线具有足够的强度,可以使用带有分析仪的测角仪进行应变扫描。Ge(111)分析仪的使用显著降低了表面像差效应。然而,从表面到50µm深度的极近表面区域仍然存在表面像差。考虑锗分析仪发散、分析仪错置和x射线衰减的影响,提出了一种校正方法。所提出的校正方法对于消除表面像差效应非常有用。该校正方法能够对地下应力分布进行高空间分辨率的评价。该方法成功地应用于喷丸钢残余应力分布的测定。利用cr - k - α辐射,利用传统的sin2ψ法测量表面应力,确定了所需的无应变晶格间距的精确d0值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of Initiation of the Interfacial Debonding in Single Fiber Composite Two Back Stress Hardening Models in Rate Independent Rigid Plastic Deformation Two Collinear Interface Cracks between Two Dissimilar Functionally Graded Piezoelectric/Piezomagnetic Material Layers under Anti-Plane Shear Loading Investigation the Dynamic Interaction between Two Collinear Cracks in the Functionally Graded Piezoelectric Materials Subjected to the Harmonic Anti-Plane Shear Stress Waves by Using the Non-Local Theory Development of a Finite Element Contact Analysis Algorithm to Pass the Patch Test
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1