{"title":"Improvement of the Gain Accuracy of the Instrumentation Amplifier Using a Very High Gain Operational Amplifier","authors":"Maitraiyee Konar, R. Sahu, S. Kundu","doi":"10.1109/DEVIC.2019.8783414","DOIUrl":null,"url":null,"abstract":"This paper evaluates the performance of three operational amplifier (Op-Amp) based instrumentation amplifier (INA) topology using two variants of Op-Amp - one with a very high gain with respect to the other Op-Amp topology. The gain accuracy and common mode rejection ratio (CMRR) of the INA is improved with the use of the very high gain Op-Amp designed using a folded cascode amplifier. The CMRR of the INA using folded cascade Op-Amp is 114 dB which is 43 dB higher to that of INA using differential amplifier.","PeriodicalId":294095,"journal":{"name":"2019 Devices for Integrated Circuit (DevIC)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Devices for Integrated Circuit (DevIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEVIC.2019.8783414","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

This paper evaluates the performance of three operational amplifier (Op-Amp) based instrumentation amplifier (INA) topology using two variants of Op-Amp - one with a very high gain with respect to the other Op-Amp topology. The gain accuracy and common mode rejection ratio (CMRR) of the INA is improved with the use of the very high gain Op-Amp designed using a folded cascode amplifier. The CMRR of the INA using folded cascade Op-Amp is 114 dB which is 43 dB higher to that of INA using differential amplifier.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用高增益运算放大器提高仪表放大器的增益精度
本文使用两种运放变体评估了三种基于运放(Op-Amp)的仪表放大器(INA)拓扑的性能,其中一种运放拓扑相对于另一种运放拓扑具有非常高的增益。采用折叠级联放大器设计的高增益运算放大器提高了INA的增益精度和共模抑制比(CMRR)。采用折叠级联运放的INA的CMRR为114 dB,比采用差分放大器的INA高43 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analytical Drain Current Model of UTBB SOI MOSFET with lateral dual gates to Suppress Short Channel Effect Effect of AlGaN Back Barrier on InAlN/AlN/GaN E-Mode HEMTs Work-function modulated hetero gate charge plasma TFET to enhance the device performance All-optical Walsh-Hadamard code Generation using MZI Performance Analysis of Staggered Heterojunction based SRG TFET biosensor for health IoT application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1