Effect of power line filter on MOV clamping voltage

M. Sudheer, M. Gunasekaran
{"title":"Effect of power line filter on MOV clamping voltage","authors":"M. Sudheer, M. Gunasekaran","doi":"10.1109/ICEMIC.1999.871662","DOIUrl":null,"url":null,"abstract":"Metal oxide varistors (MOV) are popularly used to protect offline electronic equipment against power line transients. The offline switched mode power supplies (SMPS) use power line filters and MOVs in the front-end. The power line filter is used to reduce the conducted noise emission into the power line and the MOVs connected before this line filter and the MOVs connected before this line filter to clamp line transients to safer levels thereby protecting the SMPS. Because of the presence of 'X' capacitors at the input of line filter the MOV clamping voltage is increased. This paper presents one such case and gives theoretical and experimental results. An approximate method to predetermine the magnitude of such clamping voltages is also presented.","PeriodicalId":104361,"journal":{"name":"Proceedings of the International Conference on Electromagnetic Interference and Compatibility","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the International Conference on Electromagnetic Interference and Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMIC.1999.871662","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Metal oxide varistors (MOV) are popularly used to protect offline electronic equipment against power line transients. The offline switched mode power supplies (SMPS) use power line filters and MOVs in the front-end. The power line filter is used to reduce the conducted noise emission into the power line and the MOVs connected before this line filter and the MOVs connected before this line filter to clamp line transients to safer levels thereby protecting the SMPS. Because of the presence of 'X' capacitors at the input of line filter the MOV clamping voltage is increased. This paper presents one such case and gives theoretical and experimental results. An approximate method to predetermine the magnitude of such clamping voltages is also presented.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电力线滤波器对MOV箝位电压的影响
金属氧化物压敏电阻(MOV)广泛用于保护离线电子设备免受电力线瞬变的影响。SMPS (offline switched mode power supply)前端采用电源线滤波器和MOVs。电力线滤波器用于减少传导噪声发射到电力线和连接在该线路滤波器之前的MOVs,以及连接在该线路滤波器之前的MOVs,以将线路瞬态箝位到更安全的水平,从而保护SMPS。由于在线滤波器的输入端存在“X”电容,MOV箝位电压增加。本文给出了一个实例,并给出了理论和实验结果。还提出了一种近似的方法来预先确定这种箝位电压的大小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
EMC management for an electronic system design Advanced technologies and their impact on EMC standardization and EMC measurement techniques EMI/EMC control methods during design and development of an airborne system. A case study Study of conducted susceptibility of power converters Overvoltage transient protection network design
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1