ISSUES OF DEVELOPMENT AND OPTIMIZATION OF CUVETTE TURBIDIMETERS FOR WATER TURBIDITY CONTROL

B. R. Jabbarli, M. V. Huseynova
{"title":"ISSUES OF DEVELOPMENT AND OPTIMIZATION OF CUVETTE TURBIDIMETERS FOR WATER TURBIDITY CONTROL","authors":"B. R. Jabbarli, M. V. Huseynova","doi":"10.14489/td.2022.12.pp.047-051","DOIUrl":null,"url":null,"abstract":"The issues of development and optimization of cuvette turbidimeters for water turbidity control are considered. The principle of constructing a universal turbidimeter with a variable course of the liquid beam inside the cuvette is described. The problem of optimization of cuvette laser turbidimeters in the mode of the presence of a rigid coupling function between the varying value of the initial laser radiation intensity and the length of the beam path in the liquid in the cuvette is investigated. It is shown that a turbidimeter with a changing beam path in a cuvette and a changing radiation intensity can have the highest average integral sensitivity if a decrease in the beam path is accompanied by a proportional logarithmic increase in the radiation intensity.","PeriodicalId":432853,"journal":{"name":"Kontrol'. Diagnostika","volume":"96 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kontrol'. Diagnostika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14489/td.2022.12.pp.047-051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The issues of development and optimization of cuvette turbidimeters for water turbidity control are considered. The principle of constructing a universal turbidimeter with a variable course of the liquid beam inside the cuvette is described. The problem of optimization of cuvette laser turbidimeters in the mode of the presence of a rigid coupling function between the varying value of the initial laser radiation intensity and the length of the beam path in the liquid in the cuvette is investigated. It is shown that a turbidimeter with a changing beam path in a cuvette and a changing radiation intensity can have the highest average integral sensitivity if a decrease in the beam path is accompanied by a proportional logarithmic increase in the radiation intensity.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
水浊度控制用比浊仪的研制与优化问题
讨论了用于水浊度控制的比浊仪的开发和优化问题。介绍了一种通用浊度计的原理,该浊度计的液体光束在小比皿内具有可变的运动轨迹。研究了在初始激光辐射强度变化值与试管内液体光束路径长度存在刚性耦合的情况下,试管激光浊度仪的优化问题。结果表明,如果光程的减小伴随着辐射强度的成比例的对数增加,那么当光程的变化和辐射强度的变化时,浊度计具有最高的平均积分灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
DIAGNOSTICS OF INTERELECTRODE GAP’S CONDITION USING VIBROACOUSTIC EMISSION APPLICATION OF ACOUSTIC EMISSION METHOD FOR DETECTING DIFFUSION INTERLAYERS IN DIFFERENT WELDED JOINTS CALIBRATION OF THE PIEZOELECTRIC DYNAMOMETER KISTLER USING A MEASURING DEVICE BASED ON A SAMPLE COMPRESSION DYNAMOMETER TOPOLOGY OF MANUFACTURING A SORPTION-CAPACITIVE HUMIDITY SENSOR BASED ON THIN FILMS OBTAINED BY MICROARC OXIDATION AND MAGNETRON SPUTTERING INVESTIGATION OF THE TEMPERATURE ERROR OF COORDINATE MEASURING MACHINES
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1