Partial Discharge Properties till Breakdown of Boehmite Added Enameled Twisted Pair under Bipolar Repetitive Impulse Voltage Application

S. Takenouchi, Y. Nishigaki, T. Matsuzoe, M. Kozako, Masayuki Hikita Kyushu, N. Fujimoto, N. Hayashizaka, Toshihiko Kato, Hideyuki Hideyuki
{"title":"Partial Discharge Properties till Breakdown of Boehmite Added Enameled Twisted Pair under Bipolar Repetitive Impulse Voltage Application","authors":"S. Takenouchi, Y. Nishigaki, T. Matsuzoe, M. Kozako, Masayuki Hikita Kyushu, N. Fujimoto, N. Hayashizaka, Toshihiko Kato, Hideyuki Hideyuki","doi":"10.1109/eic47619.2020.9158666","DOIUrl":null,"url":null,"abstract":"This paper presents partial discharge (PD) degradation and life characteristics of enamel twisted pair coated with nano-boehmite (AIOOH) filler added polyimide (PI) layer under bipolar repetitive impulse voltage application for developing surge resistant winding that exceeds the conventional insulation life. An attempt is also made to compare thus obtained results with those for additive-free PI sample (PI neat). An electric circuit using a capacitance connected in series with a sample was constructed to measure PD charge till breakdown (BD). Experimental results revealed the time to breakdown of boehmite/PI extended over that of PI neat, while the average PD charge increased with time and then dropped after the peak, leading to BD. This result was interpreted by the erosion suppression effect of the boehmite filler accumulating on the layer surface due to PD degradation.","PeriodicalId":286019,"journal":{"name":"2020 IEEE Electrical Insulation Conference (EIC)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/eic47619.2020.9158666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents partial discharge (PD) degradation and life characteristics of enamel twisted pair coated with nano-boehmite (AIOOH) filler added polyimide (PI) layer under bipolar repetitive impulse voltage application for developing surge resistant winding that exceeds the conventional insulation life. An attempt is also made to compare thus obtained results with those for additive-free PI sample (PI neat). An electric circuit using a capacitance connected in series with a sample was constructed to measure PD charge till breakdown (BD). Experimental results revealed the time to breakdown of boehmite/PI extended over that of PI neat, while the average PD charge increased with time and then dropped after the peak, leading to BD. This result was interpreted by the erosion suppression effect of the boehmite filler accumulating on the layer surface due to PD degradation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双极重复脉冲电压作用下薄水铝石添加搪瓷双绞线直至击穿的局部放电性能
本文研究了在双极重复冲击电压作用下,涂覆纳米薄水铝石(AIOOH)填料并添加聚酰亚胺(PI)层的搪瓷双绞线的局部放电(PD)降解和寿命特性,用于开发超过常规绝缘寿命的抗浪涌绕组。并尝试将所得结果与不加添加剂的PI样品(纯PI)进行比较。构造了一个电容与样品串联的电路,用于测量PD电荷直至击穿(BD)。实验结果表明,薄水铝石/PI的击穿时间比PI的击穿时间长,而PD的平均电荷随着时间的推移而增加,在峰值后下降,导致BD。这一结果可以解释为薄水铝石填料由于PD降解而在层表面积累了抑制侵蚀的作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Onsite Testing and Diagnosis of Medium Voltage Resin Impregnated Paper (RIP) Insulated Buses by Using Very Low Frequency High Voltage Analysis and suggestion on the chromatographic detection of inverted oil immersed current transformer Detection of Partial Discharges Occurring in Propulsion Coils of Superconducting Maglev Systems from a Test Bogie Running at High Speed Using a Radio Interferometer System with a Vector-Antenna Life expectancy of high voltage bushings based on incipient failure detections: a practical approach Approaches to the forensic failure investigation of medium voltage polymeric cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1