80 MHz three-dimensional ultrasound imaging of corneal lesions induced by cataract surgery

C. Jolly, A. Coron, M. Pérez, P. Laugier, A. Saied
{"title":"80 MHz three-dimensional ultrasound imaging of corneal lesions induced by cataract surgery","authors":"C. Jolly, A. Coron, M. Pérez, P. Laugier, A. Saied","doi":"10.1109/ULTSYM.2002.1193477","DOIUrl":null,"url":null,"abstract":"The surgery of cataract (phakoemulsification) requires the use of devices that limit the corneal incision burn. The current study aims at evaluating corneal microincision and burn induced by different phacotips using 80 MHz three dimensional (3D) ultrasonography. The study was performed in vitro on 4 fresh pig eyes. Three pig-eyes underwent clear corneal phacoemulsification, using 3 various phacomicrotips. One pig-eye served as control and underwent Clear Corneal Incision (CCI). After surgery, 3D data were acquired from the entire corneal incision volume of each eye using an 80 MHz ultrasound backscatter microscope. The -6dB axial resolution of the system was 25 /spl mu/m at focus. Thermal effects of the phakotips and generation of corneal burns were evaluated on both B-scan images and 3D volume-rendered images of the corneal tunnel reconstructed after manual delineation and selection of the incision regions. Ultrasound images allowed the visualization of corneal tunnel shape and thermal damage due to the different phakotips on the tissue. Comparative study showed the ability of high resolution 3D ultrasonography in detecting the efficiency of phakomicrotips in the prevention of corneal burns.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1193477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The surgery of cataract (phakoemulsification) requires the use of devices that limit the corneal incision burn. The current study aims at evaluating corneal microincision and burn induced by different phacotips using 80 MHz three dimensional (3D) ultrasonography. The study was performed in vitro on 4 fresh pig eyes. Three pig-eyes underwent clear corneal phacoemulsification, using 3 various phacomicrotips. One pig-eye served as control and underwent Clear Corneal Incision (CCI). After surgery, 3D data were acquired from the entire corneal incision volume of each eye using an 80 MHz ultrasound backscatter microscope. The -6dB axial resolution of the system was 25 /spl mu/m at focus. Thermal effects of the phakotips and generation of corneal burns were evaluated on both B-scan images and 3D volume-rendered images of the corneal tunnel reconstructed after manual delineation and selection of the incision regions. Ultrasound images allowed the visualization of corneal tunnel shape and thermal damage due to the different phakotips on the tissue. Comparative study showed the ability of high resolution 3D ultrasonography in detecting the efficiency of phakomicrotips in the prevention of corneal burns.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
白内障手术致角膜病变的80 MHz三维超声成像
白内障手术(晶状体乳化)需要使用限制角膜切口烧伤的装置。本研究旨在利用80 MHz三维超声技术评估不同超声针尖对角膜微切口和烧伤的影响。以4只新鲜猪眼为实验对象进行体外实验。采用3种不同的显微显微针尖对3只猪眼进行角膜透明超声乳化术。1只猪眼作为对照,行角膜透明切口(CCI)。术后使用80 MHz超声后向散射显微镜对每只眼的整个角膜切口体积进行三维数据采集。系统的-6dB轴向分辨率为25 /spl mu/m。通过人工圈定和选择切口区域后重建的角膜隧道的b扫描图像和三维体渲染图像,评估角膜切口尖端的热效应和角膜烧伤的产生。超声图像可以可视化角膜隧道形状和由于组织上不同的斑尖而引起的热损伤。对比研究表明,高分辨率三维超声可以检测显微针尖对角膜烧伤的预防效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of transducers arrays from piezoelectric hollow spheres Non-cylindrical transmission focusing for large depth of field Detection and mapping of thermal lesions using dual-mode ultrasound phased arrays Layered manufacturing for prototyping of novel transducers The effect of microbubble concentration on thresholds for tissue damage produced by single bursts of high intensity ultrasound during continuous Optison/spl reg/ infusion
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1