An Optimized Automatic P Wave Delineation Method Based on Phasor Transform

Jiayi Yan, Hanshuang Xie, Huaiyu Zhu, Yamin Liu, Fan Wu, Yun Pan
{"title":"An Optimized Automatic P Wave Delineation Method Based on Phasor Transform","authors":"Jiayi Yan, Hanshuang Xie, Huaiyu Zhu, Yamin Liu, Fan Wu, Yun Pan","doi":"10.22489/CinC.2022.122","DOIUrl":null,"url":null,"abstract":"Accurate P wave detection is important for arrhythmia diagnosis, e.g. P wave absence or P duration for atrial fibrillation diagnosis and other atrial arrhythmias. Phasor transform is an effective method for ECG fiducial points delineation. It maps each ECG sample into a phasor to enhance slight variations and preserves morphology and magnitude characteristics. In this paper, we optimized the automatic P wave delineation method based on phasor transform in four aspects, i.e., signal denoising, wave localization, candidate points detection, and optimal points selection. In our experiments, the length of the search window and the degree of phasor transform were established through various trials. Especially, along with zero-crossing points of the phasor signal, intersections of the phasor signal and the original ECG signal are obtained as candidates, which make the most contribution to delineation results. For validation, the QT Database with 3194 P wave annotations from 105 records of two leads is adopted. As a result, we reached F1 scores of 94.67% and 93.56% with detection error rates (DERs) of 10.80% and 13.06% for P wave onset and offset points detection, respectively. The F 1 score and DER for P peak detection under a tolerance of 75 ms were 95.33% and 9.46%, respectively, which outperforms other reproducible works and their combinations.","PeriodicalId":117840,"journal":{"name":"2022 Computing in Cardiology (CinC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22489/CinC.2022.122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Accurate P wave detection is important for arrhythmia diagnosis, e.g. P wave absence or P duration for atrial fibrillation diagnosis and other atrial arrhythmias. Phasor transform is an effective method for ECG fiducial points delineation. It maps each ECG sample into a phasor to enhance slight variations and preserves morphology and magnitude characteristics. In this paper, we optimized the automatic P wave delineation method based on phasor transform in four aspects, i.e., signal denoising, wave localization, candidate points detection, and optimal points selection. In our experiments, the length of the search window and the degree of phasor transform were established through various trials. Especially, along with zero-crossing points of the phasor signal, intersections of the phasor signal and the original ECG signal are obtained as candidates, which make the most contribution to delineation results. For validation, the QT Database with 3194 P wave annotations from 105 records of two leads is adopted. As a result, we reached F1 scores of 94.67% and 93.56% with detection error rates (DERs) of 10.80% and 13.06% for P wave onset and offset points detection, respectively. The F 1 score and DER for P peak detection under a tolerance of 75 ms were 95.33% and 9.46%, respectively, which outperforms other reproducible works and their combinations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于相量变换的P波自动圈定优化方法
准确的P波检测对心律失常的诊断具有重要意义,如P波缺失或P波持续时间对房颤和其他心房心律失常的诊断具有重要意义。相量变换是一种有效的心电基准点圈定方法。它将每个ECG样本映射到相量中,以增强轻微的变化并保留形态和幅度特征。本文从信号去噪、波定位、候选点检测、最优点选择四个方面对基于相量变换的P波自动圈定方法进行了优化。在我们的实验中,搜索窗口的长度和相量变换的程度是通过各种试验确定的。特别是,除了相量信号的过零点外,还获得了相量信号与原始心电信号的交点作为候选点,这对圈定结果贡献最大。为了验证,我们采用了QT数据库,其中包含了105条两导联记录的3194条P波注释。结果表明,P波起始点和偏移点检测的F1分数分别为94.67%和93.56%,检测错误率(DERs)分别为10.80%和13.06%。在容差为75 ms时,P峰检测的f1评分和DER分别为95.33%和9.46%,优于其他重复性工作及其组合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Nonlinear Dynamic Response of Intrapartum Fetal Heart Rate to Uterine Pressure Heart Pulse Demodulation from Emfit Mattress Sensor Using Spectral and Source Separation Techniques Automated Algorithm for QRS Detection in Cardiac Arrest Patients with PEA Extraction Algorithm for Morphologically Preserved Non-Invasive Multi-Channel Fetal ECG Improved Pulse Pressure Estimation Based on Imaging Photoplethysmographic Signals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1