Effect of monitoring and self-checking tests effectiveness index of back-up protection system on the optimum routine and self-checking test intervals of protection system

Y. Damchi, J. Sadeh
{"title":"Effect of monitoring and self-checking tests effectiveness index of back-up protection system on the optimum routine and self-checking test intervals of protection system","authors":"Y. Damchi, J. Sadeh","doi":"10.1109/APAP.2011.6180591","DOIUrl":null,"url":null,"abstract":"In order to maximize the availability of protection system and minimize the risk of mal-operation, usually protective relay test carry out in power electrical industry. Determination of precise optimum routine test and self-checking intervals plays a vital role in decrease of maintenance and reparation cost of protective system. Self-checking and monitoring facilities increase the reliability and optimum routine test interval of a protection system. Modern digital relays are equipped by self-checking and monitoring tests in addition to routine test however, electromagnetic and static relays are just equipped by routine test. In the previous studies, the back-up protection system is assumed to be perfectly reliable for reliability analysis. This assumption is not correct in the operation because back-up relay has the same structure on the primary relay, so back-up relay can also has mal-trip when not required and may fail to trip when required which may cause power system blackout due to cascading failure. Therefore, In this paper, an extend Markov model is proposed for reliability analysis when back-up relay is not perfectly reliable considering self-checking and monitoring facilities in the protective system. Results show that, the optimum routine and self-checking tests interval of protection system increase significantly by increasing of monitoring and self-checking tests effectiveness of back-up protection system.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"361 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

In order to maximize the availability of protection system and minimize the risk of mal-operation, usually protective relay test carry out in power electrical industry. Determination of precise optimum routine test and self-checking intervals plays a vital role in decrease of maintenance and reparation cost of protective system. Self-checking and monitoring facilities increase the reliability and optimum routine test interval of a protection system. Modern digital relays are equipped by self-checking and monitoring tests in addition to routine test however, electromagnetic and static relays are just equipped by routine test. In the previous studies, the back-up protection system is assumed to be perfectly reliable for reliability analysis. This assumption is not correct in the operation because back-up relay has the same structure on the primary relay, so back-up relay can also has mal-trip when not required and may fail to trip when required which may cause power system blackout due to cascading failure. Therefore, In this paper, an extend Markov model is proposed for reliability analysis when back-up relay is not perfectly reliable considering self-checking and monitoring facilities in the protective system. Results show that, the optimum routine and self-checking tests interval of protection system increase significantly by increasing of monitoring and self-checking tests effectiveness of back-up protection system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
后备保护系统监测和自检试验效能指标对保护系统最佳常规和自检试验间隔的影响
为了最大限度地提高保护系统的可用性,最大限度地降低误操作的风险,电力工业通常对保护继电器进行试验。确定精确的最佳例行试验和自检间隔对降低保护系统的维护和维修成本具有重要意义。自检和监测设施提高了保护系统的可靠性和最佳的例行测试间隔。现代数字继电器除进行常规试验外,还进行自检和监测试验,而电磁继电器和静态继电器仅进行常规试验。在以往的研究中,假设后备保护系统是完全可靠的,进行可靠性分析。这种假设在实际操作中是不正确的,因为备用继电器与主继电器具有相同的结构,所以备用继电器在不需要时也可能出现误跳闸,在需要时也可能跳闸失败,导致级联故障导致电力系统停电。因此,本文提出了考虑保护系统自检和监控设施的后备继电器不完全可靠时的可靠性分析扩展马尔可夫模型。结果表明,随着后备保护系统监测和自检试验有效性的提高,保护系统的最佳常规和自检试验间隔显著增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Matlab-based voltage stability analysis toolbox and its validity check Fault indicator allocation in power distribution network for improving reliability and fault section estimation Effect of monitoring and self-checking tests effectiveness index of back-up protection system on the optimum routine and self-checking test intervals of protection system A new method to prevent distance protection from operating due to power swing Coordination of overcurrent and distance relays using hybrid Particle Swarm Optimization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1