Vikash Gurugubelli, Arnab Ghosh, A. Panda, P. K. Ray, I. Sarkar
{"title":"Synchronization of Single-Phase Inverters using Deadzone and Hopf Oscillator based Controllers in Standalone Microgrid","authors":"Vikash Gurugubelli, Arnab Ghosh, A. Panda, P. K. Ray, I. Sarkar","doi":"10.1109/GlobConHT56829.2023.10087828","DOIUrl":null,"url":null,"abstract":"Virtual oscillator control (VOC) is a very popular method for the control of parallel inverters. In this work, Deadzone oscillator (DZO) based VOC and Hopf oscillator (HO) based VOC is presented to regulate the parallel inverters in a standalone microgrid (MG). The voltage amplitude and frequency reference of the inverters are coming from the oscillator dynamics. The extensive comparison of DZO and HO based control methods with different types of loads is also presented in this work. The HO based control method minimizes harmonic distortion and achieves faster time response compared to DZO based control method. The simulation results show the efficacy of the HO based control method.","PeriodicalId":355921,"journal":{"name":"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GlobConHT56829.2023.10087828","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Virtual oscillator control (VOC) is a very popular method for the control of parallel inverters. In this work, Deadzone oscillator (DZO) based VOC and Hopf oscillator (HO) based VOC is presented to regulate the parallel inverters in a standalone microgrid (MG). The voltage amplitude and frequency reference of the inverters are coming from the oscillator dynamics. The extensive comparison of DZO and HO based control methods with different types of loads is also presented in this work. The HO based control method minimizes harmonic distortion and achieves faster time response compared to DZO based control method. The simulation results show the efficacy of the HO based control method.