V. Anghel, G. Pristavu, G. Brezeanu
{"title":"Forcing the limits — Peak voltage extension for floating buck controller","authors":"V. Anghel, G. Pristavu, G. Brezeanu","doi":"10.1109/ISSCS.2013.6651259","DOIUrl":null,"url":null,"abstract":"A solution for increasing a current mode floating buck controller's versatility, through the use of a peak voltage extension block, is investigated, implemented and its performances are measured. Most current controller architectures have limitations that impose harsh application-constraints. This paper proposes a new method of reducing those limitations by allowing precise, linear, external control of the peak voltage threshold. The solution is especially useful in applications where each instance of the buck controller needs to be individually adjusted to meet specifications.","PeriodicalId":260263,"journal":{"name":"International Symposium on Signals, Circuits and Systems ISSCS2013","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Signals, Circuits and Systems ISSCS2013","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSCS.2013.6651259","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A solution for increasing a current mode floating buck controller's versatility, through the use of a peak voltage extension block, is investigated, implemented and its performances are measured. Most current controller architectures have limitations that impose harsh application-constraints. This paper proposes a new method of reducing those limitations by allowing precise, linear, external control of the peak voltage threshold. The solution is especially useful in applications where each instance of the buck controller needs to be individually adjusted to meet specifications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
强制限制。浮动降压控制器的峰值电压扩展
通过使用峰值电压扩展块,研究并实现了一种增加电流模式浮动降压控制器通用性的解决方案,并对其性能进行了测量。大多数当前的控制器架构都有限制,施加了苛刻的应用程序约束。本文提出了一种新的方法,通过允许对峰值电压阈值进行精确的线性外部控制来减少这些限制。在需要单独调整降压控制器的每个实例以满足规范的应用程序中,该解决方案特别有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Autor index Dynamic time warping for speech recognition with training part to reduce the computation A face recognition system based on a Kinect sensor and Windows Azure cloud technology An efficient GSC VSS-APA beamformer with integrated log-energy based VAD for noise reduction in speech reinforcement systems RNSIC-1 based wind energy conversion
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1