On the Dental BioTribology: Comparison of Zirconia/Zirconia and Zirconia/Natural Tooth Friction Coefficients by Using a Reciprocating Tribometer

A. Ruggiero, R. D’Amato, L. Sbordone, F. Haro, A. Lanza
{"title":"On the Dental BioTribology: Comparison of Zirconia/Zirconia and Zirconia/Natural Tooth Friction Coefficients by Using a Reciprocating Tribometer","authors":"A. Ruggiero, R. D’Amato, L. Sbordone, F. Haro, A. Lanza","doi":"10.1145/3284179.3284254","DOIUrl":null,"url":null,"abstract":"In recent years the interest of tribology applied to dentistry is taking on a large scale due to its rapid expansion and growth. Intensive experimental research conducted on dental tribology allows to develop a more detailed understanding of all the phenomena that take part in the phenomenon of tooth wear. The purpose of this work is to investigate tribological performances in the tooth-to-tooth contact and material-to-natural tooth contact (zirconia vs. zirconia and natural tooth vs. zirconia). The tribological tests were carried out by using a reciprocating tribometer under lubricated conditions (artificial saliva). The normal force in these tests was 20 N, and the duration was of 60 min. The stroke length was 2 mm, according to the range of displacement used in scientific literature. The wear mass loss evaluation was evaluated by using a gravimetric method. A topographic analysis was carried with a 3D non-contact optical profiler in order to characterize the wear mechanisms present in the worn surfaces after each of tribo-tests. The results show that the minimum value of the COF is obtained in the case of Zirconia vs. Zirconia tribo-couple, corresponding to 0.49±0.03. In the case of the tooth-tooth couple this value is 0.52 ±0.03. The results on the wear mass loss show a very low wear rate when coupling in tribological condition natural tooth with a ceramic restoration (a mean value of 0.5 mg was found). This rate is even lower when the contact is between two artificial zirconia teeth.","PeriodicalId":370465,"journal":{"name":"Proceedings of the Sixth International Conference on Technological Ecosystems for Enhancing Multiculturality","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Sixth International Conference on Technological Ecosystems for Enhancing Multiculturality","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3284179.3284254","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

In recent years the interest of tribology applied to dentistry is taking on a large scale due to its rapid expansion and growth. Intensive experimental research conducted on dental tribology allows to develop a more detailed understanding of all the phenomena that take part in the phenomenon of tooth wear. The purpose of this work is to investigate tribological performances in the tooth-to-tooth contact and material-to-natural tooth contact (zirconia vs. zirconia and natural tooth vs. zirconia). The tribological tests were carried out by using a reciprocating tribometer under lubricated conditions (artificial saliva). The normal force in these tests was 20 N, and the duration was of 60 min. The stroke length was 2 mm, according to the range of displacement used in scientific literature. The wear mass loss evaluation was evaluated by using a gravimetric method. A topographic analysis was carried with a 3D non-contact optical profiler in order to characterize the wear mechanisms present in the worn surfaces after each of tribo-tests. The results show that the minimum value of the COF is obtained in the case of Zirconia vs. Zirconia tribo-couple, corresponding to 0.49±0.03. In the case of the tooth-tooth couple this value is 0.52 ±0.03. The results on the wear mass loss show a very low wear rate when coupling in tribological condition natural tooth with a ceramic restoration (a mean value of 0.5 mg was found). This rate is even lower when the contact is between two artificial zirconia teeth.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
牙齿生物摩擦学研究:用往复摩擦计比较氧化锆/氧化锆和氧化锆/天然牙齿摩擦系数
近年来,摩擦学在牙科领域的发展迅速,引起了广泛的关注。对牙齿摩擦学进行深入的实验研究,可以更详细地了解牙齿磨损现象的所有现象。这项工作的目的是研究牙齿与牙齿接触和材料与自然牙齿接触(氧化锆与氧化锆和自然牙齿与氧化锆)的摩擦学性能。在润滑条件下(人工唾液)使用往复式摩擦计进行摩擦学试验。这些试验的法向力为20牛,持续时间为60分钟,行程长度为2毫米,根据科学文献中使用的位移范围。用重量法对磨损质量损失进行了评价。使用三维非接触式光学剖面仪进行地形分析,以表征每次摩擦试验后磨损表面存在的磨损机制。结果表明,氧化锆对氧化锆摩擦偶的COF最小值为0.49±0.03;对于齿-齿耦合,该值为0.52±0.03。磨损质量损失的结果表明,在摩擦学条件下,天然牙与陶瓷修复体耦合时,磨损率非常低(平均值为0.5 mg)。当两颗人造氧化锆牙齿接触时,这一比率甚至更低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A complete psychophysiological profile of a Paralympic athlete in a ultraendurance: A case study Design and prototyping by additive manufacturing of a functional splint for rehabilitation of Achilles tendon intrasubstance rupture Experience in the implementation of projects in professional environment in a 1st cycle of studies of Civil Engineering Development and use of mobile technologies that foster students' evaluative judgement: a design-based research Academic digital books: The publishing industry VS Openness in book reading
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1