{"title":"Comparison of electrical characteristics of barbed-plate and wire-plate precipitators","authors":"P. J. McKinney, Jane H. Davidson","doi":"10.1109/IAS.1993.299105","DOIUrl":null,"url":null,"abstract":"Differences in electrical characteristics of barbed plate-to-plate and wire-plate precipitators are presented in terms of measured current-voltage curves and spatial distributions of current at the collection plate. Data are obtained in a 61.0 cm by 61.0 cm by 15.2 cm laboratory precipitator operating at Reynolds and electrohydrodynamic numbers typical of industrial precipitators. Results show that a barbed plate-to-plate precipitator produces more uniform distributions of current along the collector plates than exist in a conventional wire-plate precipitator.<<ETX>>","PeriodicalId":345027,"journal":{"name":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1993.299105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
Differences in electrical characteristics of barbed plate-to-plate and wire-plate precipitators are presented in terms of measured current-voltage curves and spatial distributions of current at the collection plate. Data are obtained in a 61.0 cm by 61.0 cm by 15.2 cm laboratory precipitator operating at Reynolds and electrohydrodynamic numbers typical of industrial precipitators. Results show that a barbed plate-to-plate precipitator produces more uniform distributions of current along the collector plates than exist in a conventional wire-plate precipitator.<>
通过测量的电流-电压曲线和收集板处电流的空间分布,给出了倒刺板对板和线板除尘器电特性的差异。数据是在雷诺数下运行的61.0 cm × 61.0 cm × 15.2 cm的实验室除尘器和典型工业除尘器的电流体动力学数值中获得的。结果表明,与传统的线板除尘器相比,倒刺板对板除尘器沿集电板的电流分布更为均匀。