{"title":"An experimental study of surge protection in smart meter installation in the residential sector","authors":"Kashyap Mamta, Tiwari Shruti","doi":"10.26634/jee.16.3.19449","DOIUrl":null,"url":null,"abstract":"This paper aims to construct an experimental system using the Arduino UNO microcontroller board to measure the electrical quantities and protect against surge circumstances in a single-phase power supply. The system utilized a voltage sensor and a current sensor, and data was transferred to a personal computer for graphical examination. The Root Mean Square (RMS) method was used to measure electrical values, and the system is allowed to decide whether to turn the load on or off based on the comparison of RMS voltage measurement to the lowest and maximum voltages. The Telemetry Viewer v0.5 software was used to create the monitoring interface, which monitored the system's RMS voltage, RMS current, active power, and trip signal.","PeriodicalId":403999,"journal":{"name":"i-manager’s Journal on Electrical Engineering","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"i-manager’s Journal on Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26634/jee.16.3.19449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper aims to construct an experimental system using the Arduino UNO microcontroller board to measure the electrical quantities and protect against surge circumstances in a single-phase power supply. The system utilized a voltage sensor and a current sensor, and data was transferred to a personal computer for graphical examination. The Root Mean Square (RMS) method was used to measure electrical values, and the system is allowed to decide whether to turn the load on or off based on the comparison of RMS voltage measurement to the lowest and maximum voltages. The Telemetry Viewer v0.5 software was used to create the monitoring interface, which monitored the system's RMS voltage, RMS current, active power, and trip signal.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
住宅领域智能电表安装中浪涌保护的实验研究
本文旨在利用Arduino UNO微控制器板构建一个实验系统,用于单相电源的电量测量和浪涌保护。该系统采用电压传感器和电流传感器,并将数据传输到个人计算机进行图形化检测。采用均方根(RMS)法测量电学值,系统根据RMS电压测量值与最低和最高电压的比较来决定是否接通或关闭负载。使用Telemetry Viewer v0.5软件创建监控界面,监控系统的RMS电压、RMS电流、有功功率和跳闸信号。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
PHASOR ANALYSIS FOR ACTIVE POWER FLOW CONTROL OF AUTONOMOUS INDUCTION GENERATOR FEEDING ENERGY IMMUNE ETP An approach of battery energy management systems for DC micro-grids considering stateflow controller Efficiency and Reliability Evaluation of IGBT Valve Based 48 Pulse Converter UPFC Passive balancing in battery management system for electrical vehicles Reduction of common mode voltage for cascaded 3-level inverter using SVPWM
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1