A laboratory set-up for power quality disturbance generator and real time power quality monitoring

Chetan B. Khadse, M. Chaudhari, V. Borghate
{"title":"A laboratory set-up for power quality disturbance generator and real time power quality monitoring","authors":"Chetan B. Khadse, M. Chaudhari, V. Borghate","doi":"10.1109/WIECON-ECE.2016.8009088","DOIUrl":null,"url":null,"abstract":"Solid State relay based single phase power quality disturbance generator is proposed in this paper. Digital control system based on microcontroller 89C51 is implemented to control the duration of power quality disturbances. Voltage sag, swell and interruption are generated. Dimmerstat is used to change the voltage levels and so to control the intensity of disturbances. Design of proposed generator is discussed. Simple design and use of easily available components makes this generator economic. It is highly suitable in power quality laboratory for experimental work. Students working on voltage sag/swell compensation and monitoring of power quality events can use this generator. Proposed generator is used as an application for PC based real time power quality monitoring system. Monitoring system is designed in LabVIEW. For fetching the real time signal, voltage sensor and data acquisition system are used. Results of real time detection of disturbances and classification of disturbances into momentary, temporary, instantaneous and under voltage or over voltage are done by monitoring system and presented in this paper.","PeriodicalId":412645,"journal":{"name":"2016 IEEE International WIE Conference on Electrical and Computer Engineering (WIECON-ECE)","volume":"109 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International WIE Conference on Electrical and Computer Engineering (WIECON-ECE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WIECON-ECE.2016.8009088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Solid State relay based single phase power quality disturbance generator is proposed in this paper. Digital control system based on microcontroller 89C51 is implemented to control the duration of power quality disturbances. Voltage sag, swell and interruption are generated. Dimmerstat is used to change the voltage levels and so to control the intensity of disturbances. Design of proposed generator is discussed. Simple design and use of easily available components makes this generator economic. It is highly suitable in power quality laboratory for experimental work. Students working on voltage sag/swell compensation and monitoring of power quality events can use this generator. Proposed generator is used as an application for PC based real time power quality monitoring system. Monitoring system is designed in LabVIEW. For fetching the real time signal, voltage sensor and data acquisition system are used. Results of real time detection of disturbances and classification of disturbances into momentary, temporary, instantaneous and under voltage or over voltage are done by monitoring system and presented in this paper.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电能质量扰动发生器和电能质量实时监测的实验室装置
提出了一种基于固态继电器的单相电能质量扰动发生器。基于单片机89C51实现了电能质量扰动持续时间的数字控制系统。产生电压凹陷、膨胀和中断。调光器用于改变电压水平,从而控制干扰的强度。讨论了该发电机的设计。简单的设计和使用容易获得的组件,使该发电机经济。它非常适用于电能质量实验室的实验工作。从事电压跌落/膨胀补偿和电能质量事件监测的学生可以使用该发电机。该发电机在基于PC机的电能质量实时监测系统中得到了应用。在LabVIEW中设计了监控系统。为了获取实时信号,采用了电压传感器和数据采集系统。本文介绍了监测系统实时检测干扰的结果,并将干扰分为瞬时、暂态、瞬时、欠压或过压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The interference management and cost analysis perspective of femtocell in 4G network Magnetic levitation of solar powered motor with forward-reverse operation: Mathematical design consideration Image hashing by CCQ-CSLBP Fabrication of FeTiO3/SiO2 matrix based sensors for glucose detection in blood Grid connected hybrid solar system with MPPT charge controller
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1