Differential diagnosis of aseptic and septic loosening of the cup of the artificial hip joint endoprosthesis by methods of spectral-selective laser autofluorescence microscopy
V. Vasyuk, A. Kalashnikov, V. Protsyuk, I. Soltys, A. Motrich, Y. Ushenko, P. Gorodenskiy, V. Gantyuk
{"title":"Differential diagnosis of aseptic and septic loosening of the cup of the artificial hip joint endoprosthesis by methods of spectral-selective laser autofluorescence microscopy","authors":"V. Vasyuk, A. Kalashnikov, V. Protsyuk, I. Soltys, A. Motrich, Y. Ushenko, P. Gorodenskiy, V. Gantyuk","doi":"10.1117/12.2616672","DOIUrl":null,"url":null,"abstract":"The paper presents a structural and logical diagram and an analytical description of the differential diagnosis of aseptic and septic loosening of the cup of an artificial hip joint endoprosthesis using spectral-selective laser autofluorescence microscopy of coordinate distribution maps (MIF) and correlation (MCF) fluorescence intensity of polycrystalline films of synovial fluid (SF). The results of the statistical analysis [1-5] of the distributions of the MIF and MCF values of polycrystalline SF films of patients from the control group and groups with different severity of pathology of the hip joint are presented. The sensitivity, specificity and accuracy [6-9] of the method of spectral-selective laser autofluorescence microscopy MIF and MCF of the fluorescence intensity of polycrystalline films of hip joint CF have been established.","PeriodicalId":250235,"journal":{"name":"International Conference on Correlation Optics","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Correlation Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2616672","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The paper presents a structural and logical diagram and an analytical description of the differential diagnosis of aseptic and septic loosening of the cup of an artificial hip joint endoprosthesis using spectral-selective laser autofluorescence microscopy of coordinate distribution maps (MIF) and correlation (MCF) fluorescence intensity of polycrystalline films of synovial fluid (SF). The results of the statistical analysis [1-5] of the distributions of the MIF and MCF values of polycrystalline SF films of patients from the control group and groups with different severity of pathology of the hip joint are presented. The sensitivity, specificity and accuracy [6-9] of the method of spectral-selective laser autofluorescence microscopy MIF and MCF of the fluorescence intensity of polycrystalline films of hip joint CF have been established.