Condition Monitoring of IGBT Module Based on Peak Rise Rate Appearance Time of Case Temperature during the Start-up Process of Converter

Jinyang Li, Yaoyi Yu, Xiong Du
{"title":"Condition Monitoring of IGBT Module Based on Peak Rise Rate Appearance Time of Case Temperature during the Start-up Process of Converter","authors":"Jinyang Li, Yaoyi Yu, Xiong Du","doi":"10.1109/CEECT55960.2022.10030696","DOIUrl":null,"url":null,"abstract":"In this paper, we proposed a new method to monitor the IGBT thermal path degradation of IGBT module using the peak rise rate appearance time of case temperature right below the center of the chip during the start-up process of converter. The correlation between the peak rise rate appearance time and 3rd-order Cauer thermal parameters is analyzed. Results show that the degradation of IGBT module can be monitored by detecting the peak rise rate appearance time. Simulation and experimental tests are performed to verify the effectiveness of the proposed method.","PeriodicalId":187017,"journal":{"name":"2022 4th International Conference on Electrical Engineering and Control Technologies (CEECT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 4th International Conference on Electrical Engineering and Control Technologies (CEECT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEECT55960.2022.10030696","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, we proposed a new method to monitor the IGBT thermal path degradation of IGBT module using the peak rise rate appearance time of case temperature right below the center of the chip during the start-up process of converter. The correlation between the peak rise rate appearance time and 3rd-order Cauer thermal parameters is analyzed. Results show that the degradation of IGBT module can be monitored by detecting the peak rise rate appearance time. Simulation and experimental tests are performed to verify the effectiveness of the proposed method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于变流器启动过程中箱体温度峰值上升率出现时间的IGBT模块状态监测
本文提出了一种利用变换器启动过程中芯片正下方外壳温度峰值上升率出现时间监测IGBT模块IGBT热路径退化的新方法。分析了峰升率出现时间与三阶Cauer热参数的关系。结果表明,可以通过检测峰值上升率出现时间来监测IGBT模块的退化情况。仿真和实验验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An optimization model based interval power flow analysis method considering the tracking characteristic of static voltage generator Design of Liquid Level Monitoring and Alarm System in Transformer Accident Oil Pool Mechanism Analysis of the SSR Suppression in DFIG-Based Wind farm Systems with SVCs Evaluation Method of Aging State of Oil-Paper Insulation Based on Time Domain Dielectric Response Study on the Effect of Multi-circuit Laying on Ampacity of Low Smoke Halogen-free Cable
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1