V. Bitney, N. Smotrov, Alexander An. Timofeev, A. Okhlopkov
{"title":"Effect of the Reactive Power Consumption Mode on the Technical Condition of the T3FP-110-2MU3 Turbogenerator","authors":"V. Bitney, N. Smotrov, Alexander An. Timofeev, A. Okhlopkov","doi":"10.1109/REEPE57272.2023.10086802","DOIUrl":null,"url":null,"abstract":"The necessity of turbogenerators’ operation in the reactive power consumption mode is determined by the shortage of compensating devices in the network. Recently, accidents associated with generators’ long-term operation at low levels of excitation have become more frequent, which is a prerequisite for the consumption of reactive power by the generator. The purpose of this research is to assess the effect of the reactive power consumption mode on the technical condition of the T3FP-110-2MU3 turbogenerator. Data obtained from operating and repair documentation, electrical and thermal test protocols, technical reports containing the results of complex diagnostic examinations of the turbogenerator served as a source of information on the technical condition of the turbogenerator.","PeriodicalId":356187,"journal":{"name":"2023 5th International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 5th International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REEPE57272.2023.10086802","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The necessity of turbogenerators’ operation in the reactive power consumption mode is determined by the shortage of compensating devices in the network. Recently, accidents associated with generators’ long-term operation at low levels of excitation have become more frequent, which is a prerequisite for the consumption of reactive power by the generator. The purpose of this research is to assess the effect of the reactive power consumption mode on the technical condition of the T3FP-110-2MU3 turbogenerator. Data obtained from operating and repair documentation, electrical and thermal test protocols, technical reports containing the results of complex diagnostic examinations of the turbogenerator served as a source of information on the technical condition of the turbogenerator.