{"title":"Effects of UPFC on measured impedance by distance relay in double-circuit lines","authors":"S. Jamali, A. Kazemi, H. Shateri","doi":"10.1109/PES.2009.5275344","DOIUrl":null,"url":null,"abstract":"This paper presents the measured impedance at the relaying point in the presence of Unified Power Flow Controller (UPFC), one of Flexible Alternating Current Transmission System (FACTS) devices, on a double circuit transmission line. The presence of UPFC on a line has a great influence on the measured impedance at the relaying point. The measured impedance itself depends on the power system structural conditions, pre-fault loading, and especially the ground fault resistance. In the presence of UPFC, its structural and controlling parameters as well as its installation location affect the measured impedance. The measured impedance at relaying point is evaluated due to the concerning parameters.","PeriodicalId":258632,"journal":{"name":"2009 IEEE Power & Energy Society General Meeting","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2009.5275344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper presents the measured impedance at the relaying point in the presence of Unified Power Flow Controller (UPFC), one of Flexible Alternating Current Transmission System (FACTS) devices, on a double circuit transmission line. The presence of UPFC on a line has a great influence on the measured impedance at the relaying point. The measured impedance itself depends on the power system structural conditions, pre-fault loading, and especially the ground fault resistance. In the presence of UPFC, its structural and controlling parameters as well as its installation location affect the measured impedance. The measured impedance at relaying point is evaluated due to the concerning parameters.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
UPFC对双回路上距离继电器测量阻抗的影响
本文介绍了在双回路传输线上,在有统一潮流控制器(UPFC)的情况下,继电点的阻抗测量。UPFC是柔性交流输电系统(FACTS)的一种器件。线路上UPFC的存在对继电点处的测量阻抗有很大的影响。被测阻抗本身取决于电力系统的结构条件、故障前负荷,特别是接地故障电阻。在UPFC存在的情况下,其结构参数、控制参数以及安装位置都会影响被测阻抗。根据相关参数对继电点的测量阻抗进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Substation fault analysis requirements On field experience results related to high-impedance faults in power distribution system Reactive power compensation using Z-source based photovoltaic system How can flicker level be determined before a customer is connected to the electric grid Transmission expansion and pricing in Colombia: An appraisal of current practices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1