High temperature modification of XLPE exposed to partial discharges

M. Gamez-Garcia, R. Bartnikas, M. Wertheimer
{"title":"High temperature modification of XLPE exposed to partial discharges","authors":"M. Gamez-Garcia, R. Bartnikas, M. Wertheimer","doi":"10.1109/ICSD.1989.69220","DOIUrl":null,"url":null,"abstract":"Results of surface degradation studies of XLPE (cross-linked polyethylene) under corona discharges at elevated temperature are presented. Corona was applied for durations up to 24 hr, during which time the sample temperature was maintained constant at a selected value between 20 degrees C and 160 degrees C. Corona pulse-height distributions were monitored during the exposure period using a multichannel analyzer. After corona treatment, the specimens were analyzed by several physical and chemical techniques. Results on the evolution of reaction products and on surface and bulk oxidation are presented.<<ETX>>","PeriodicalId":184126,"journal":{"name":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1989.69220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Results of surface degradation studies of XLPE (cross-linked polyethylene) under corona discharges at elevated temperature are presented. Corona was applied for durations up to 24 hr, during which time the sample temperature was maintained constant at a selected value between 20 degrees C and 160 degrees C. Corona pulse-height distributions were monitored during the exposure period using a multichannel analyzer. After corona treatment, the specimens were analyzed by several physical and chemical techniques. Results on the evolution of reaction products and on surface and bulk oxidation are presented.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
局部放电下交联聚乙烯的高温改性
介绍了高温电晕放电下交联聚乙烯(XLPE)表面降解的研究结果。电晕的持续时间长达24小时,在此期间,样品温度保持在20摄氏度到160摄氏度之间的选定值。在暴露期间,使用多通道分析仪监测电晕脉冲高度分布。电晕处理后,对样品进行了理化分析。给出了反应产物的演化、表面氧化和本体氧化的研究结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On the mechanism of partial discharges in gaseous cavities in contact with solid or liquid insulators The initiation and growth of AC tree in polyethylene Effects of the field dependent occupation of electrical-stress-generated traps on the conduction and breakdown of thin SiO/sub 2/ films A model of the electrical breakdown process due to electrical treeing growth Dielectric breakdown and partial discharge in BaTiO/sub 3/ ceramics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1