A gamma ray imager using clustered non-redundant array coded aperture

L. Meng, D. Wehe
{"title":"A gamma ray imager using clustered non-redundant array coded aperture","authors":"L. Meng, D. Wehe","doi":"10.1109/NSSMIC.2003.1351810","DOIUrl":null,"url":null,"abstract":"This paper presents the design and initial experimental results of a gamma camera using a coded aperture with clustered non-redundant array pattern. This system is based on the use of 5\" position sensitive photomultiplier tube coupled to pixelated BGO array with 2/spl times/2/spl times/10mm/sup 3/ pixels. The PSPMT is readout by the IDEAS VA-MCR system with a costume made front electronic. This gamma camera was designed for imaging gamma rays with a broad energy range. The collimator plate was made of Tungsten of 8 mm thick for reducing the effect of gamma ray penetration. For imaging source objects with a relatively large angular extent and high background, the use of clustered NRA offers great flexibility in aperture design that provides a wide view angle and a controlled data multiplexing. In order to replace the time consuming Monte Carlo simulations, we also presented an analytical method for calculating performance indices, such as pixel-wise signal-to-noise ratio and resolution/variance tradeoffs achievable with different detector designs. This helps to select an approximate aperture for given imaging tasks.","PeriodicalId":186175,"journal":{"name":"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2003.1351810","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents the design and initial experimental results of a gamma camera using a coded aperture with clustered non-redundant array pattern. This system is based on the use of 5" position sensitive photomultiplier tube coupled to pixelated BGO array with 2/spl times/2/spl times/10mm/sup 3/ pixels. The PSPMT is readout by the IDEAS VA-MCR system with a costume made front electronic. This gamma camera was designed for imaging gamma rays with a broad energy range. The collimator plate was made of Tungsten of 8 mm thick for reducing the effect of gamma ray penetration. For imaging source objects with a relatively large angular extent and high background, the use of clustered NRA offers great flexibility in aperture design that provides a wide view angle and a controlled data multiplexing. In order to replace the time consuming Monte Carlo simulations, we also presented an analytical method for calculating performance indices, such as pixel-wise signal-to-noise ratio and resolution/variance tradeoffs achievable with different detector designs. This helps to select an approximate aperture for given imaging tasks.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种采用聚类非冗余阵列编码孔径的伽马射线成像仪
本文介绍了一种编码孔径聚类非冗余阵列伽玛相机的设计和初步实验结果。该系统基于使用5英寸位置敏感光电倍增管耦合到像素化BGO阵列,具有2/spl倍/2/spl倍/10mm/sup 3/像素。PSPMT是由IDEAS VA-MCR系统与服装制作的前电子读出。这台伽马照相机是为宽能量范围的伽马射线成像而设计的。准直板采用8毫米厚的钨材料,以减小射线穿透的影响。对于具有相对大角度范围和高背景的成像源对象,使用集群NRA在光圈设计上提供了很大的灵活性,提供了宽视角和可控的数据复用。为了取代耗时的蒙特卡罗模拟,我们还提出了一种计算性能指标的分析方法,例如不同检测器设计可实现的像素级信噪比和分辨率/方差权衡。这有助于为给定的成像任务选择一个近似孔径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Proton irradiation response of CsI(Tl) crystals for the GLAST calorimeter Comparative study of PP0275C hybrid photodetector and XP2020Q photomultiplier in scintillation detection Quality of mass produced lead tungstate crystals SLIM (Secondary emission monitor for Low Interception Monitoring) an innovative non-destructive beam monitor for the extraction lines of a hadrontherapy center Single electron amplification in a "Single-MCP + micromegas + pads" detector
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1