3D reconstruction of both shape and Bone Mineral Density distribution of the femur from DXA images

L. Humbert, T. Whitmarsh, M. D. Craene, L. D. R. Barquero, K. Fritscher, R. Schubert, F. Eckstein, T. Link, Alejandro F Frangi
{"title":"3D reconstruction of both shape and Bone Mineral Density distribution of the femur from DXA images","authors":"L. Humbert, T. Whitmarsh, M. D. Craene, L. D. R. Barquero, K. Fritscher, R. Schubert, F. Eckstein, T. Link, Alejandro F Frangi","doi":"10.1109/ISBI.2010.5490310","DOIUrl":null,"url":null,"abstract":"The diagnosis of osteoporosis and the prevention of femur fractures is a major challenge for our society. However, the diagnosis performed in clinical routine from Dual Energy X-ray Absorptiometry (DXA) images is limited. This paper proposes a 3D reconstruction method of both the shape and the Bone Mineral Density (BMD) distribution of the proximal femur from routinely used DXA images. The reconstruction accuracy that can be obtained from single-view and multi-view DXA devices was assessed. This evaluation, from 20 bone specimens and simulated DXA images, highlighted a mean shape accuracy of 1.3mm and a BMD accuracy of 4.4% from a single-view DXA image. A multi-view configuration with 2 views (frontal-sagittal) appeared as a good compromise (mean shape accuracy of 0.9mm and BMD accuracy of 3.2%). We are currently using this method for in vivo clinical studies in order to improve the diagnosis of osteoporosis and the prevention of femur fractures.","PeriodicalId":250523,"journal":{"name":"2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2010.5490310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

The diagnosis of osteoporosis and the prevention of femur fractures is a major challenge for our society. However, the diagnosis performed in clinical routine from Dual Energy X-ray Absorptiometry (DXA) images is limited. This paper proposes a 3D reconstruction method of both the shape and the Bone Mineral Density (BMD) distribution of the proximal femur from routinely used DXA images. The reconstruction accuracy that can be obtained from single-view and multi-view DXA devices was assessed. This evaluation, from 20 bone specimens and simulated DXA images, highlighted a mean shape accuracy of 1.3mm and a BMD accuracy of 4.4% from a single-view DXA image. A multi-view configuration with 2 views (frontal-sagittal) appeared as a good compromise (mean shape accuracy of 0.9mm and BMD accuracy of 3.2%). We are currently using this method for in vivo clinical studies in order to improve the diagnosis of osteoporosis and the prevention of femur fractures.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
DXA图像对股骨形状和骨密度分布的三维重建
骨质疏松症的诊断和股骨骨折的预防是我们社会面临的主要挑战。然而,临床常规双能x线吸收仪(DXA)图像的诊断是有限的。本文提出了一种基于常规DXA图像的股骨近端形状和骨密度(BMD)分布的三维重建方法。评估了单视图和多视图DXA设备可以获得的重建精度。该评估来自20个骨标本和模拟DXA图像,突出显示单视图DXA图像的平均形状精度为1.3mm, BMD精度为4.4%。2个视图(额矢状面)的多视图配置似乎是一个很好的折衷(平均形状精度为0.9mm, BMD精度为3.2%)。我们目前正在使用这种方法进行体内临床研究,以提高骨质疏松症的诊断和股骨骨折的预防。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Enhanced detection of cell paths in spatiotemporal plots for noninvasive microscopy of the human retina Automatic segmentation of pulmonary vasculature in thoracic CT scans with local thresholding and airway wall removal Fast and closed-form ensemble-average-propagator approximation from the 4th-order diffusion tensor Probabilistic branching node detection using AdaBoost and hybrid local features Multiphase level set for automated delineation of membrane-bound macromolecules
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1