{"title":"Scan-based testability for fault-tolerant architectures","authors":"A. DeHon","doi":"10.1109/DFTVS.1992.224372","DOIUrl":null,"url":null,"abstract":"The acceptance and use of standard scan-based test access ports (TAPs), such as the IEEE-1149.1-1990 standard, have begun to ease the task of system testability and in-circuit diagnostics. The typical singular nature of these TAPs along with the all-or-nothing manner in which test facilities are accessed make such standard TAPs inappropriate for use in fault-tolerant architectures. The authors propose three simple additions to standard scan practices which allow scan techniques to be effectively utilized in fault-tolerant environments. Specifically, they advocate the incorporation of multiple-TAPs, port-by-port selection control, and partial external scan. Multi-TAP construction offers tolerance to faults in the scan path or circuitry. Port-by-port selection and partial external scan allow fault-diagnostics which are minimally intrusive and in-operation reconfiguration for fault-masking and repair.<<ETX>>","PeriodicalId":319218,"journal":{"name":"Proceedings 1992 IEEE International Workshop on Defect and Fault Tolerance in VLSI Systems","volume":"125 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 1992 IEEE International Workshop on Defect and Fault Tolerance in VLSI Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DFTVS.1992.224372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
The acceptance and use of standard scan-based test access ports (TAPs), such as the IEEE-1149.1-1990 standard, have begun to ease the task of system testability and in-circuit diagnostics. The typical singular nature of these TAPs along with the all-or-nothing manner in which test facilities are accessed make such standard TAPs inappropriate for use in fault-tolerant architectures. The authors propose three simple additions to standard scan practices which allow scan techniques to be effectively utilized in fault-tolerant environments. Specifically, they advocate the incorporation of multiple-TAPs, port-by-port selection control, and partial external scan. Multi-TAP construction offers tolerance to faults in the scan path or circuitry. Port-by-port selection and partial external scan allow fault-diagnostics which are minimally intrusive and in-operation reconfiguration for fault-masking and repair.<>