{"title":"Verification of the Usefulness of Radiotracing Methods in Hydrodynamic Investigations","authors":"A. Chmielewski, A. Dobrowolski","doi":"10.1080/10256018608623712","DOIUrl":null,"url":null,"abstract":"In the paper comparison of accuracy of two methods used for investigations of hydrodynamic in continuous flow tanks has been made. Basis for the comparison is the experimental work performed for big industrial wastewater concentration equalization tank. The first method is based on the radiotracer experiment while the second one uses the analysis of response on sudden change of the technological parameters. The radiotracer method has better accuracy connected with the shorter sampling period. Ks wird die Genauigkeit zweier Methoden zur Untersuchting der Hydrodynamik von kontinuierlich arbeitenden Flussigkeitsbehaltern verglichen. Grundlage dafur sind experimentelle Untersuchungen an groβen Industrieabwasser-Ausgleichsbehaltern. Die erste Methode bedient sich der Radiotracertechnik, wahrend die zweite Methode auf einer plotzlichen Veranderung der technologischcn Parameter beruht. Es zeigt sich, daβ die Radiotracermethoden die besseren Ergebnisse liefert, wobei auβerdem noch kurzere Probenaltmeperioden von ...","PeriodicalId":404027,"journal":{"name":"November 1986","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1986-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"November 1986","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10256018608623712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In the paper comparison of accuracy of two methods used for investigations of hydrodynamic in continuous flow tanks has been made. Basis for the comparison is the experimental work performed for big industrial wastewater concentration equalization tank. The first method is based on the radiotracer experiment while the second one uses the analysis of response on sudden change of the technological parameters. The radiotracer method has better accuracy connected with the shorter sampling period. Ks wird die Genauigkeit zweier Methoden zur Untersuchting der Hydrodynamik von kontinuierlich arbeitenden Flussigkeitsbehaltern verglichen. Grundlage dafur sind experimentelle Untersuchungen an groβen Industrieabwasser-Ausgleichsbehaltern. Die erste Methode bedient sich der Radiotracertechnik, wahrend die zweite Methode auf einer plotzlichen Veranderung der technologischcn Parameter beruht. Es zeigt sich, daβ die Radiotracermethoden die besseren Ergebnisse liefert, wobei auβerdem noch kurzere Probenaltmeperioden von ...