Comparison between three methods to value lower tear meniscus measured by image software

C. García-Resúa, Hugo Pena-Verdeal, M. Lira, M. Oliveira, M. .. Giraldez, E. Yebra-Pimentel
{"title":"Comparison between three methods to value lower tear meniscus measured by image software","authors":"C. García-Resúa, Hugo Pena-Verdeal, M. Lira, M. Oliveira, M. .. Giraldez, E. Yebra-Pimentel","doi":"10.1117/12.2030433","DOIUrl":null,"url":null,"abstract":"To measure different parameters of lower tear meniscus height (TMH) by using photography with open software of measurement. TMH was addressed from lower eyelid to the top of the meniscus (absolute TMH) and to the brightest meniscus reflex (reflex TMH). 121 young healthy subjects were included in the study. The lower tear meniscus was videotaped by a digital camera attached to a slit lamp. Three videos were recorded in central meniscus portion on three different methods: slit lamp without fluorescein instillation, slit lamp with fluorescein instillation and TearscopeTM without fluorescein instillation. Then, a masked observed obtained an image from each video and measured TMH by using open source software of measurement based on Java (NIH ImageJ). Absolute central (TMH-CA), absolute with fluorescein (TMH-F) and absolute using the Tearscope (TMH-Tc) were compared each other as well as reflex central (TMH-CR) and reflex Tearscope (TMH-TcR). Mean ± S.D. values of TMH-CA, TMH-CR, TMH-F, TMH-Tc and TMH-TcR of 0.209 ± 0.049, 0.139 ± 0.031, 0.222 ± 0.058, 0.175 ± 0.045 and 0.109 ± 0.029 mm, respectively were found. Paired t-test was performed for the relationship between TMH-CA – TMH-CR, TMH-CA – TMH-F, TMH-CA – TMH-Tc, TMH-F – TMH-Tc, TMH-Tc – TMH-TcR and TMH-CR – TMH-TcR. In all cases, it was found a significant difference between both variables (all p < 0.008). This study showed a useful tool to objectively measure TMH by photography. Eye care professionals should maintain the same TMH parameter in the follow-up visits, due to the difference between them.","PeriodicalId":135913,"journal":{"name":"Iberoamerican Meeting of Optics and the Latin American Meeting of Optics, Lasers and Their Applications","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iberoamerican Meeting of Optics and the Latin American Meeting of Optics, Lasers and Their Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2030433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

To measure different parameters of lower tear meniscus height (TMH) by using photography with open software of measurement. TMH was addressed from lower eyelid to the top of the meniscus (absolute TMH) and to the brightest meniscus reflex (reflex TMH). 121 young healthy subjects were included in the study. The lower tear meniscus was videotaped by a digital camera attached to a slit lamp. Three videos were recorded in central meniscus portion on three different methods: slit lamp without fluorescein instillation, slit lamp with fluorescein instillation and TearscopeTM without fluorescein instillation. Then, a masked observed obtained an image from each video and measured TMH by using open source software of measurement based on Java (NIH ImageJ). Absolute central (TMH-CA), absolute with fluorescein (TMH-F) and absolute using the Tearscope (TMH-Tc) were compared each other as well as reflex central (TMH-CR) and reflex Tearscope (TMH-TcR). Mean ± S.D. values of TMH-CA, TMH-CR, TMH-F, TMH-Tc and TMH-TcR of 0.209 ± 0.049, 0.139 ± 0.031, 0.222 ± 0.058, 0.175 ± 0.045 and 0.109 ± 0.029 mm, respectively were found. Paired t-test was performed for the relationship between TMH-CA – TMH-CR, TMH-CA – TMH-F, TMH-CA – TMH-Tc, TMH-F – TMH-Tc, TMH-Tc – TMH-TcR and TMH-CR – TMH-TcR. In all cases, it was found a significant difference between both variables (all p < 0.008). This study showed a useful tool to objectively measure TMH by photography. Eye care professionals should maintain the same TMH parameter in the follow-up visits, due to the difference between them.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
图像软件测量下撕裂半月板价值的三种方法比较
采用开放式测量软件,采用摄影法测量下撕裂半月板高度(TMH)的不同参数。从下眼睑到半月板顶部(绝对TMH)和最亮的半月板反射(反射TMH)。121名年轻健康受试者被纳入研究。用连接在裂隙灯上的数码相机记录下下半月板撕裂情况。采用不注射荧光素的裂隙灯、注射荧光素的裂隙灯和不注射荧光素的TearscopeTM三种不同的方法在半月板中央部分记录三段视频。然后,利用基于Java的开源测量软件(NIH ImageJ),利用掩模观测者从每个视频中获取图像,测量TMH。比较绝对中央(TMH-CA)、荧光素绝对(TMH-F)和泪镜绝对(TMH-Tc)以及反射中央(TMH-CR)和反射泪镜绝对(TMH-TcR)。TMH-CA、TMH-CR、TMH-F、TMH-Tc和TMH-TcR的平均±sd值分别为0.209±0.049、0.139±0.031、0.222±0.058、0.175±0.045和0.109±0.029 mm。对TMH-CA - TMH-CR、TMH-CA - TMH-F、TMH-CA - TMH-Tc、TMH-F - TMH-Tc、TMH-Tc - TMH-TcR、TMH-CR - TMH-TcR之间的关系进行配对t检验。在所有情况下,发现两个变量之间存在显著差异(均p < 0.008)。本研究提供了一种有用的工具来客观地测量TMH的摄影。眼保健专业人员在随访时应保持相同的TMH参数,因为它们之间存在差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Remote access to an interferometric fringes stabilization active system via RENATA Optical design of a Coudé-Train for a stable and efficient simultaneous feeding of the ESPRESSO spectrograph from the four VLT telescopes Configurable multipulsing of a MOPA pulsed fiber laser with applications in materials processing New method for sub-structured Ronchi rulings generation and his irradiance profile Photorefractive moiré-like patterns with different variation directions for multi-projection in profilometer applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1