{"title":"Can oversampling improve the dynamics of PWM controls?","authors":"J. Bocker, O. Buchholz","doi":"10.1109/ICIT.2013.6505952","DOIUrl":null,"url":null,"abstract":"Regular Sampling is the state of the art when employing digital discrete-time control to pulse width-modulated systems. However, the fact that the dynamics of discrete-time control is below that of an analog continuous-time control is often not being aware. The paper shows that digital control dynamics can be improved with oversampling, i.e. employing a higher rate for sampling and controller updating as with Regular Sampling without increasing the pulse frequency. As a result, it is shown that already an oversampling rate of about 8 to 16 provides approximately the same dynamics of a continuous-time control. The benefits of even higher oversampling rates are of minor significance, which can be understood as a clear design recommendation. Though the consideration is carried out with a simplified circuitry, the results are of general meaning and can be transferred easily to application in the area of drive control or switched-mode power supplies.","PeriodicalId":192784,"journal":{"name":"2013 IEEE International Conference on Industrial Technology (ICIT)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"46","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Industrial Technology (ICIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2013.6505952","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 46
Abstract
Regular Sampling is the state of the art when employing digital discrete-time control to pulse width-modulated systems. However, the fact that the dynamics of discrete-time control is below that of an analog continuous-time control is often not being aware. The paper shows that digital control dynamics can be improved with oversampling, i.e. employing a higher rate for sampling and controller updating as with Regular Sampling without increasing the pulse frequency. As a result, it is shown that already an oversampling rate of about 8 to 16 provides approximately the same dynamics of a continuous-time control. The benefits of even higher oversampling rates are of minor significance, which can be understood as a clear design recommendation. Though the consideration is carried out with a simplified circuitry, the results are of general meaning and can be transferred easily to application in the area of drive control or switched-mode power supplies.