Research on reflective pulse oximetry based on fiber optic spectrometer

Zheng Liu, Dezhi Zheng, Wei Zhou, Meiling Zhou
{"title":"Research on reflective pulse oximetry based on fiber optic spectrometer","authors":"Zheng Liu, Dezhi Zheng, Wei Zhou, Meiling Zhou","doi":"10.1109/ICSENST.2016.7796304","DOIUrl":null,"url":null,"abstract":"Human oxygen saturation detection is based on the Lambert-Beer Law, but since the human body is a strong scattering tissue instead of a homogeneous medium, the influence of scattering need to be considered, which means the basic Lambert-Beer Law is not applicable. In this paper, a fiber optic spectrometer is used to detect the blood oxygen saturation in vivo with reflective method. Based on the dynamic spectrum theory, the concept of equivalent attenuation is proposed, converting the three-dimensional data measured in real time into two-dimensional characteristic spectral data. In spite of the baseline drift and dark noise of the spectrometer, the two-dimensional characteristic spectral data can be corrected by multiple scatter correction, which can eliminate the influence of the scattering and baseline drift, and improve the accuracy of the model building.","PeriodicalId":297617,"journal":{"name":"2016 10th International Conference on Sensing Technology (ICST)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 10th International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2016.7796304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Human oxygen saturation detection is based on the Lambert-Beer Law, but since the human body is a strong scattering tissue instead of a homogeneous medium, the influence of scattering need to be considered, which means the basic Lambert-Beer Law is not applicable. In this paper, a fiber optic spectrometer is used to detect the blood oxygen saturation in vivo with reflective method. Based on the dynamic spectrum theory, the concept of equivalent attenuation is proposed, converting the three-dimensional data measured in real time into two-dimensional characteristic spectral data. In spite of the baseline drift and dark noise of the spectrometer, the two-dimensional characteristic spectral data can be corrected by multiple scatter correction, which can eliminate the influence of the scattering and baseline drift, and improve the accuracy of the model building.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于光纤光谱仪的反射式脉搏血氧仪研究
人体血氧饱和度检测基于朗伯-比尔定律,但由于人体是强散射组织而非均匀介质,因此需要考虑散射的影响,这意味着基本的朗伯-比尔定律不适用。本文采用光纤光谱仪,用反射法检测体内血氧饱和度。基于动态频谱理论,提出等效衰减的概念,将实时测量的三维数据转换为二维特征光谱数据。尽管光谱仪存在基线漂移和暗噪声,但通过多次散射校正可以对二维特征光谱数据进行校正,消除了散射和基线漂移的影响,提高了模型建立的精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Advanced AODV approach for efficient detection and mitigation of wormhole attack in MANET Taste sensor using strongly hydrophobic membranes to measure hydrophobic substances Optimal design work for high-frequency quartz resonators A novel hybrid based recommendation system based on clustering and association mining Highly sensitive visible and near-infrared photo-FET based on PbS quantum dots embedded in the gate insulator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1