Monitoring of Orientation of Cells by Electric Impedance: Test on Oriented Cells Using Micro Striped Grooves Pattern by Photolithography

S. Hashimoto, Kazuyuki Abe
{"title":"Monitoring of Orientation of Cells by Electric Impedance: Test on Oriented Cells Using Micro Striped Grooves Pattern by Photolithography","authors":"S. Hashimoto, Kazuyuki Abe","doi":"10.1109/BIBE.2019.00106","DOIUrl":null,"url":null,"abstract":"The electric impedance has been measured to estimate the orientation of cells in vitro. To arrange the orientation, several parallel lines of micro rectangular grooves (1 µm depth, 3 µm width and interval) have been made between a pair of the surface titanium electrodes on the scaffold of glass by the photolithography technique. Two types of arrangements of lines were designed related to the micro grooves: parallel, and perpendicular to the electric line of force between electrodes. C2C12 (mouse myoblast cell line) was cultured on the micro-patterned scaffold. The electric impedance (Z) between electrodes was measured every 24 hours with the sinusoidal electric waves (frequency, 1 kHz < f < 10 MHz; amplitude, v = ± 0.05 V) for three days. The number of oriented cells (Ns) was defined by the number of cells, which cross the straight-line bands of 0.01 mm width connecting between electrodes. The experimental result shows that Z increases with Ns. The phase difference between the voltage and the current is larger at the arrangement of myoblasts oriented in the perpendicular position than that in the parallel position. The present study shows that the measurement of the electric impedance is effective to estimate the orientation of cells.","PeriodicalId":318819,"journal":{"name":"2019 IEEE 19th International Conference on Bioinformatics and Bioengineering (BIBE)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 19th International Conference on Bioinformatics and Bioengineering (BIBE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIBE.2019.00106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The electric impedance has been measured to estimate the orientation of cells in vitro. To arrange the orientation, several parallel lines of micro rectangular grooves (1 µm depth, 3 µm width and interval) have been made between a pair of the surface titanium electrodes on the scaffold of glass by the photolithography technique. Two types of arrangements of lines were designed related to the micro grooves: parallel, and perpendicular to the electric line of force between electrodes. C2C12 (mouse myoblast cell line) was cultured on the micro-patterned scaffold. The electric impedance (Z) between electrodes was measured every 24 hours with the sinusoidal electric waves (frequency, 1 kHz < f < 10 MHz; amplitude, v = ± 0.05 V) for three days. The number of oriented cells (Ns) was defined by the number of cells, which cross the straight-line bands of 0.01 mm width connecting between electrodes. The experimental result shows that Z increases with Ns. The phase difference between the voltage and the current is larger at the arrangement of myoblasts oriented in the perpendicular position than that in the parallel position. The present study shows that the measurement of the electric impedance is effective to estimate the orientation of cells.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用电阻抗监测细胞的取向:用光刻技术对定向细胞进行微条纹凹槽图案的测试
测定了电阻抗来估计细胞在体外的取向。通过光刻技术,在玻璃支架上的一对表面钛电极之间制作了几条平行线(深度为1µm,宽度为3µm,间距为3µm)的微型矩形凹槽,以排列方向。设计了两种与微凹槽相关的线的排列方式:平行和垂直于电极之间的电力线。小鼠成肌细胞系C2C12在微花纹支架上培养。电极之间的电阻抗(Z)每24小时测量一次,使用正弦波(频率,1 kHz < f < 10 MHz;振幅,v =±0.05 v)三天。取向细胞的数量(Ns)由细胞的数量来定义,这些细胞穿过连接电极之间0.01 mm宽的直线带。实验结果表明,Z随Ns的增大而增大。成肌细胞垂直排列时,电压和电流的相位差比平行排列时大。研究表明,电阻抗的测量是估计细胞取向的有效方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stability Investigation Using Hydrogen Bonds for Different Mutations and Drug Resistance in Non-Small Cell Lung Cancer Patients A Temporal Convolution Network Solution for EEG Motor Imagery Classification Evaluation of a Serious Game Promoting Nutrition and Food Literacy: Experiment Design and Preliminary Results Towards a Robust and Accurate Screening Tool for Dyslexia with Data Augmentation using GANs Exploring Fibrotic Disease Networks to Identify Common Molecular Mechanisms with IPF
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1